Benchtop Carbon Fiber Microelectrode Array Fabrication Toolkit

BackgroundConventional neural probes are primarily fabricated in a cleanroom, requiring the use of multiple expensive and highly specialized tools. New methodWe propose a cleanroom "light" fabrication process of carbon fiber neural electrode arrays that can be learned quickly by an inexperienced cleanroom user. This carbon fiber electrode array fabrication process requires just one cleanroom tool, a parylene-c deposition machine, that can be learned quickly or outsourced to a commercial processing facility at marginal cost. Our fabrication process also includes hand-populating printed circuit boards, insulation, and tip optimization. ResultsThe three different tip optimizations explored here (Nd:YAG laser, blowtorch, and UV laser) result in a range of tip geometries and 1kHz impedances, with blowtorched fibers resulting in the lowest impedance. While previous experiments have proven laser and blowtorch electrode efficacy, this paper also shows UV laser cut fibers can record neural signals in vivo. Comparison with existing methodsExisting carbon fiber arrays either do not have individuated electrodes in favor of bundles or require cleanroom fabricated guides for population and insulation. The proposed arrays use only tools that can be used at a benchtop for fiber population. ConclusionsThis carbon fiber electrode array fabrication process allows for quick customization of bulk array fabrication at a reduced price compared to commercially available probes.

bioengineering

Sharpened and mechanically robust carbon fiber electrode arrays for neural interfacing

Bioelectric medicine treatments target disorders of the nervous system unresponsive to pharmacological methods. While current stimulation paradigms effectively treat many disorders, the underlying mechanisms are relatively unknown, and current neuroscience recording electrodes are often limited in their specificity to gross averages across many neurons or axons. Here, we develop a novel, durable carbon fiber electrode array adaptable to many neural structures for precise neural recording. Carbon fibers were sharpened using a reproducible blowtorch method that uses the reflection of fibers against the surface of a water bath. The arrays were developed by partially embedding carbon fibers in medical-grade silicone to improve durability. We recorded acute spontaneous electrophysiology from the rat cervical vagus nerve (CVN), feline dorsal root ganglia (DRG), and rat brain. Blowtorching resulted in fibers of 72.3 {+/-} 33.5 degree tip angle with 146.8 {+/-} 17.7 m exposed carbon. Silicone-embedded carbon fiber arrays were durable with 87.5% of fibers remaining after 50,000 passes. Observable neural clusters were recorded using sharpened carbon fiber electrodes from rat CVN (41.8 Vpp), feline DRG (101.1 Vpp), and rat brain (80.7 Vpp). Recordings from the feline DRG included physiologically-relevant signals from increased bladder pressure and cutaneous brushing. These results suggest that this carbon fiber array is a uniquely durable and adaptable neural recording device. In the future, this device may be useful as a bioelectric medicine tool for diagnosis and closed-loop neural control of therapeutic treatments and monitoring systems.

bioengineering

Real-Time Linear Prediction of Simultaneous and Independent Movements of Two Finger Groups Using an Intracortical Brain-Machine Interface

Modern brain-machine interfaces can return function to people with paralysis, but current hand neural prostheses are unable to reproduce control of individuated finger movements. Here, for the first time, we present a real-time, high-speed, linear brain-machine interface in nonhuman primates that utilizes intracortical neural signals to bridge this gap. We created a novel task that systematically individuates two finger groups, the index finger and the middle-ring-small fingers combined, presenting separate targets for each group. During online brain control, the ReFIT Kalman filter demonstrated the capability of individuating movements of each finger group with high performance, enabling a nonhuman primate to acquire two targets simultaneously at 1.95 targets per second, resulting in an average information throughput of 2.1 bits per second. To understand this result, we performed single unit tuning analyses. Cortical neurons were active for movements of an individual finger group, combined movements of both finger groups, or both. Linear combinations of neural activity representing individual finger group movements predicted the neural activity during combined finger group movements with high accuracy, and vice versa. Hence, a linear model was able to explain how cortical neurons encode information about multiple dimensions of movement simultaneously. Additionally, training ridge regressing decoders with independent component movements was sufficient to predict untrained higher-complexity movements. Our results suggest that linear decoders for brain-machine interfaces may be sufficient to execute high-dimensional tasks with the performance levels required for naturalistic neural prostheses.

bioengineering

Lentiviral interleukin-10 gene therapy preserves fine motor circuitry and function after a cervical spinal cord injury in male and female mice

In mammals, spinal cord injuries often result in muscle paralysis through the apoptosis of lower motor neurons and denervation of neuromuscular junctions. Previous research shows that the inflammatory response to a spinal cord injury can cause additional tissue damage after the initial trauma. To modulate this inflammatory response, we delivered lentiviral anti-inflammatory interleukin-10, via loading onto an implantable biomaterial scaffold, into a left-sided hemisection at the C5 vertebra in mice. We hypothesized that improved behavioral outcomes associated with anti-inflammatory treatment are due to the sparing of fine motor circuit components. We examined behavioral recovery using a ladder beam, lower motor neuron apoptosis and muscle innervation using histology, and electromyogram recordings using intraspinal optogenetic stimulation at 2 weeks post-injury. Ladder beam analysis shows interleukin-10 treatment results in significant improvement of behavioral recovery at 2 and 12 weeks post-injury when compared to mice treated with a control virus. Histology shows interleukin-10 results in greater numbers of lower motor neurons and muscle innervation at 2 weeks post-injury. Furthermore, electromyogram recordings suggest that interleukin-10-treated animals have signal-to-noise ratios and peak-to-peak amplitudes more similar to that of uninjured controls than to that of control injured animals at 2 weeks post-injury. These data show that gene therapy using anti-inflammatory interleukin-10 can significantly reduce lower motor neuron loss, muscle denervation, and subsequent motor deficits after a spinal cord injury. Together, these results suggest that early modulation of the injury response can preserve muscle function with long-lasting benefits.

neuroscience

Cellular-scale silicon probes for high-density, precisely-localized neurophysiology

Neural implants with large numbers of electrodes have become an important tool for examining brain functions. However, these devices typically displace a large intracranial volume compared to the neurons they record. This large size limits the density of implants, provokes tissue reactions that degrade chronic performance, and impedes the ability to accurately visualize recording sites within intact circuits. Here we report next-generation silicon-based neural probes at cellular-scale (5x10{micro}m cross-section), with ultra-high-density packing (as little as 66{micro}m between shanks) and 64 or 256 closely-spaced recording sites per probe. We show that these probes can be inserted into superficial or deep brain structures and maintain high-quality spike recordings in freely behaving rats for many weeks. Finally, we demonstrate a slice-in-place approach for the precise registration of recording sites relative to nearby neurons and anatomical features, including striatal {micro}-opioid receptor patches. This scalable technology provides a valuable tool for examining information processing within neural circuits, and potentially for human brain-machine interfaces.

bioengineering

Multi-channel intraneural vagus nerve recordings with a novel high-density carbon fiber microelectrode array

Autonomic nerves convey essential neural signals that regulate vital body functions. Recording clearly distinctive physiological neural signals from autonomic nerves will help develop new treatments for restoring regulatory functions. However, this is very challenging due to the small nature of autonomic nerves and the low-amplitude signals from their small axons. We developed a multi-channel, high-density, intraneural carbon fiber microelectrode array (CFMA) with ultra-small electrodes (8-9 m in diameter, 150-250 m in length) for recording physiological action potentials from small autonomic nerves. In this study, we inserted CFMA with up to 16 recording carbon fibers in the cervical vagus nerve of 22 isoflurane-anesthetized rats. We recorded action potentials with peak-to-peak amplitudes of 15.1-91.7 V and signal-to-noise ratios of 2.0-8.3 on multiple carbon fibers per experiment, determined conduction velocities of some vagal signals in the afferent (0.7-4.4 m/sec) and efferent (0.7-8.8 m/sec) directions, and monitored firing rate changes in breathing and blood glucose modulated conditions. Overall, these experiments demonstrated that CFMA is a novel interface for in-vivo intraneural action potential recordings. This work is considerable progress towards the comprehensive understanding of physiological neural signaling in vital regulatory functions controlled by autonomic nerves.

bioengineering