Search bioRxiv⌕ Search

Biology subjects

Buttafava, M.

Publications and source records attributed to Buttafava, M..

5 recordsLinked to original sources

Robustness of time domain near infrared spectroscopy to variations in skin pigmentation

Recently, skin pigmentation has been shown to affect the performance of pulse oximeters and other light-based techniques like photoacoustic imaging, tissue oximetry, and continuous wave near infrared spectroscopy. Evaluating the robustness to changes in skin pigmentation is therefore essential for the proper use of optical technologies in the clinical scenario. We conducted systematic time domain near infrared spectroscopy measurements on calibrated tissue phantoms and in vivo on volunteers during static and dynamic (i.e., arterial occlusion) measurements. To simulate varying melanosome volume fractions in the skin, we inserted, between the target sample and the measurement probe, thin tissue phantoms made of silicone and nigrosine (skin phantoms). Additionally, we conducted an extensive measurement campaign on a large cohort of pediatric subjects, covering the full spectrum of skin pigmentation. Our findings consistently demonstrate that skin pigmentation has a negligible effect on time domain near infrared spectroscopy results, underscoring the reliability and potential of this emerging technology in diverse clinical settings.

bioengineering↗

In vivo characterization of the optical and hemodynamic properties of the human sternocleidomastoid muscle through ultrasound-guided hybrid near-infrared spectroscopies.

The non-invasive monitoring of the hemodynamics and metabolism of the sternocleidomastoid muscle (SCM) during respiration became a topic of increased interest partially due to the increased use of mechanical ventilation during the COVID-19 pandemic. Near-infrared diffuse optical spectroscopies were proposed as potential practical monitors of increased recruitment of SCM during respiratory distress. They can provide clinically relevant information on the degree of the patients respiratory effort that is needed to maintain an optimal minute ventilation, with potential clinical application ranging from evaluating chronic pulmonary diseases to more acute settings, such as acute respiratory failure, or to determine the readiness to wean from invasive mechanical ventilation. In this paper, we present a detailed characterization of the optical properties (wave-length dependent absorption and reduced scattering coefficients) and hemodynamic properties (oxy-, deoxy- and total hemoglobin concentrations, blood flow, blood oxygen saturation and metabolic rate of oxygen extraction) of the human SCM, obtained by measuring sixty-five subjects through ultrasound-guided near-infrared time-resolved and diffuse correlation spectroscopies. We provide detailed tables of the results related to SCM baseline (i.e. muscle at rest) properties, and reveal significant differences on the measured parameters due to variables such as side of the neck, sex, age, body mass index and thickness of the overlaying tissues, allowing future clinical studies to take into account such dependencies.

physiology↗

Cooled SPAD array detector for low light-dose fluorescence laser scanning microscopy

The single-photon timing and sensitivity performance and the imaging ability of asynchronous-readout single-photon avalanche diode (SPAD) array detectors have opened up enormous perspectives in fluorescence (lifetime) laser scanning microscopy (FLSM), such as super-resolution image scanning microscopy and high-information content fluorescence fluctuation spectroscopy (FFS). However, the strengths of these FLSM techniques depend on the many different characteristics of the detector, such as dark-noise, photon-detection efficiency, after-pulsing probability, and optical-cross talk, whose overall optimization is typically a trade-off between these characteristics. To mitigate this trade-off, we present a novel SPAD array detector with an active cooling system, which substantially reduces the dark-noise without significantly deteriorating any other detector characteristics. In particular, we show that lowering the temperature of the sensor to -15{degrees}C significantly improves the signal-to-noise ratio due to a 10-fold decrease in the dark-count rate compared to room temperature. As a result, for imaging, the laser power can be decreased by more than a factor of three, which is particularly beneficial for live-cell super-resolution imaging, as demonstrated in fixed and living cells expressing GFP-tagged proteins. For FFS, together with the benefit of the reduced laser power, we show that cooling the detector is necessary to remove artifacts in the correlation function, such as spurious negative correlations observed in the hot elements of the detector, i.e., elements whose dark-noise is substantially higher than the median value. Overall, this detector represents a further step towards the integration of SPAD array detectors in any FLSM system. SIGNIFICANCESingle-photon avalanche diode (SPAD) array detectors are revolutionizing fluorescence laser-scanning microscopy (FLSM). Thanks to their single-photon timing and sensitivity ability and their imaging faculty, a SPAD array detector transforms any FLSM into a super-resolution microscope, and opens a whole range of possibilities for the study of sample dynamics by means of fluorescence fluctuation spectroscopy (FFS). However, dark-noise can be a severe problem for both imaging and FFS. For imaging, the signal overcomes noise only for a relatively high illumination intensity, which can be detrimental for live-cell experiments. For FFS, the noise leads to artifacts in the correlation curves, potentially leading to wrong conclusions about the sample. We show that lowering the temperature of the detector to -15{degrees}C solves both problems

biophysics↗

Easy Two-Photon Image Scanning Microscopy with SPAD Array and Blind Image Reconstruction

Two-photon excitation (2PE) microscopy is the imaging modality of choice, when one desires to work with thick biological samples, possibly in-vivo. However, the resolution in two-photon microscopy is poor, below confocal microscopy, and the lack of an optical pinhole becomes apparent in complex samples as reduced quality of optical sectioning. Here, we propose a straightforward implementation of 2PE image scanning microscopy (2PE-ISM) that, by leveraging our recently introduced ISM platform - based on a new single-photon avalanche diode array detector - coupled with a novel blind image reconstruction method, is shown to improve the optical resolution, as well as the overall image quality in various test samples. Most importantly, our 2PE-ISM implementation requires no calibration or other input from the user - it works like any old and familiar two-photon system, but simply produces higher resolution images (in real-time). Making the complexity disappear, in our view, is the biggest novelty here, and the key for making 2PE-ISM mainstream.

bioengineering↗

Image Scanning Microscopy with Single-Photon Detector Array

Image scanning microscopy (ISM) improves the spatial resolution of conventional confocal laser-scanning microscopy (CLSM), but current implementations reduce versatility and restrict its combination with fluorescence spectroscopy techniques, such as fluorescence lifetime. Here, we describe a natural design of ISM based on a fast single-photon detector array, which allows straightforward upgrade of an existing confocal microscope, without compromising any of its functionalities. In contrast to all-optical ISM implementations, our approach provides access to the raw scanned images, opening the way to adaptive reconstruction methods, capable of considering different imaging conditions and distortions. We demonstrate its utility in the context of fluorescence lifetime, deep, multicolor and live-cell imaging. This implementation will pave the way for a transparent and massive transition from conventional CLSM to ISM.\n\nconfocal microscopy | time-resolved spectroscopy | image scanning microscopy | single-photon detector array

bioengineering↗