Search bioRxiv⌕ Search

Biology subjects

Bousgouni, V.

Publications and source records attributed to Bousgouni, V..

5 recordsLinked to original sources

Multi-Site Reproducibility Study of 3D High-Content Analysis with Dual-View Oblique Plane Microscopy

High content imaging is being applied to achieve quantitative fluorescence readouts in increasingly complex 3-dimensional (3D) cell culture models such as spheroids and organoids. Compared to conventional 2D assays, 3D assays better represent biological heterogeneity but require more complex sample preparation, 3D imaging and 3D image analysis that can affect the accuracy and precision of such assays. We used spheroids formed from the NRAS-activated melanoma cell line 19161 modified to express an ERK kinase translocation reporter (KTR) as an exemplar 3D phenotypic assay carried out in 96-well plates. The spheroids were treated with the ERK activator TPA and a range of concentrations of the MEK inhibitor Binimetinib. 3D live-cell imaging with sub-cellular spatial resolution was performed using a dual-view oblique plane microscope (dOPM) - a form of single-objective light-sheet microscope - and the experiment was performed separately at 4 different institutes. The results were analysed using an identical 3D analysis pipeline and parameters. We assessed the variation in assay readout using a linear mixed effects model. Random variance at the well level was negligible (SD = 0.0048 relative to range of KTR biosensor readout at reference site of 0.17), indicating low technical noise. Treatment effects were dose-dependent and highly statistically significant compared to DMSO control across all sites (Dunnett-corrected p < 0.001). The range in KTR readout between the minimum (3.5 M Binimetinib) and maximum (100 nM TPA) treatments varied between 59 to 96% relative to the reference site. Measured bias in KTR readout between sites was between 6 and 12% of the range of the reference site. This study quantifies the reproducibility of a 3D live spheroid-based assay employing a fluorescence biosensor requiring readout out at the per-cell level using the dOPM platform and discusses areas where experimental protocol could be improved in the future to further improve reproducibility.

bioengineering↗

Biocompatibility characterisation of CMOS-based Lab-on-Chip electrochemical sensors for in vitro cancer cell culture applications

Lab-on-Chip electrochemical sensors, such as Ion-Sensitive Field-Effect Transistors (ISFETs), are being developed for use in point-of-care diagnostics, such as pH detection of tumour microenvironments, due to their integration with standard Complementary Metal Oxide Semiconductor technology. With this approach, the passivation of the CMOS process is used as a sensing layer to minimise post-processing, and Silicon Nitride (Si3N4) is the most common material at the microchip surface. ISFETs have the potential to be used for cell-based assays however, there is a poor understanding of the biocompatibility of microchip surfaces. Here, we quantitatively evaluated cell adhesion, morphogenesis, proliferation and mechano-responsiveness of both normal and cancer cells cultured on a Si3N4, sensor surface. We demonstrate that both normal and cancer cell adhesion decreased on Si3N4. Activation of the mechano-responsive transcription regulators, YAP/TAZ, are significantly decreased in cancer cells on Si3N4 in comparison to standard cell culture plastic, whilst proliferation marker, Ki67, expression markedly increased. Non-tumorigenic cells on chip showed less sensitivity to culture on Si3N4 than cancer cells. Treatment with extracellular matrix components increased cell adhesion in normal and cancer cell cultures, surpassing the adhesiveness of plastic alone. Moreover, poly-l-ornithine and laminin treatment restored YAP/TAZ levels in both non-tumorigenic and cancer cells to levels comparable to those observed on plastic. Thus, engineering the electrochemical sensor surface with treatments will provide a more physiologically relevant environment for future cell-based assay development on chip.

cancer biology↗

Environmentally dependent and independent control of cell shape determination by Rho GTPase regulators in melanoma

In order to invade 3D tissues, cancer cells dynamically change cell morphology in response to geometric and mechanical cues in the environment. But how cells determine their shape in 3D versus 2D environments is poorly understood. Studying 2D versus 3D single cell shape determination has historically been technically difficult due to the lack of methodologies to directly compare the two environments. We developed an approach to study cell shape in 2D versus 3D by measuring cell shape at different depths in collagen using stage-scanning oblique plane microscopy (ssOPM). We find characteristic shape changes occur in melanoma cells depending on whether a cell is attached to a 2D surface or 3D environment, and that these changes can be modulated by Rho GTPase regulatory proteins. Our data suggest that regulation of cell protrusivity undergoes a switch of control between different Rho GTPase regulators depending on the physical microenvironment.

cell biology↗

Robust optical autofocus system utilizing neural networks trained for extended range and time-course and automated multiwell plate imaging including single molecule localization microscopy

We present a robust, long-range optical autofocus system for microscopy utilizing machine learning. This can be useful for experiments with long image data acquisition times that may be impacted by defocusing resulting from drift of components, e.g. due to changes in temperature or mechanical drift. It is also useful for automated slide scanning or multiwell plate imaging where the sample(s) to be imaged may not be in the same horizontal plane throughout the image data acquisition. To address the impact of (thermal or mechanical) fluctuations over time in the optical autofocus system itself, we utilise a convolutional neural network (CNN) that is trained over multiple days to account for such fluctuations. To address the trade-off between axial precision and range of the autofocus, we implement orthogonal optical readouts with separate CNN training data, thereby achieving an accuracy well within the 600 nm depth of field of our 1.3 numerical aperture objective lens over a defocus range of up to approximately +/- 100 m. We characterise the performance of this autofocus system and demonstrate its application to automated multiwell plate single molecule localisation microscopy.

bioengineering↗

A high-content RNAi screen reveals multiple roles for long noncoding RNAs in cell division

Genome stability relies on proper coordination of mitosis and cytokinesis, where dynamic microtubules capture and faithfully segregate chromosomes into daughter cells. The role of long noncoding RNAs (lncRNAs) in controlling these processes however remains largely unexplored. To identify lncRNAs with mitotic functions, we performed a high-content RNAi imaging screen targeting more than 2,000 human lncRNAs. By investigating major hallmarks of cell division such as chromosome segregation, mitotic duration and cytokinesis, we discovered numerous lncRNAs with functions in each of these processes. The chromatin-associated lncRNA, linc00899, was selected for in-depth studies due to the robust mitotic delay observed upon its depletion. Transcriptome analysis of linc00899-depleted cells together with gain-of-function and rescue experiments across multiple cell types identified the neuronal microtubule-binding protein, TPPP/p25, as a target of linc00899. Linc00899 binds the genomic locus of TPPP/p25 and suppresses its transcription through a cis-acting mechanism. In cells depleted of linc00899, the consequent upregulation of TPPP/p25 alters microtubule dynamics and is necessary and sufficient to delay mitosis. Overall, our comprehensive screen identified several lncRNAs with roles in genome stability and revealed a new lncRNA that controls microtubule behaviour with functional implications beyond cell division.

cell biology↗