Search bioRxiv⌕ Search

Biology subjects

Bourdieu, L.

Publications and source records attributed to Bourdieu, L..

6 recordsLinked to original sources

Streamlined Production of Recombinant Adeno-Associated Viruses Using Gateway Cloning Technology for Neural Circuit All-Optical Interrogation

The advent of optogenetics and the rapid development of genetically encoded actuators and reporters for calcium, voltage, neurotransmitters, and other molecules have revolutionized neuroscience research by enabling precise, non-invasive optical interrogation of neural circuits. Successful implementation, however, critically depends on efficient reporter expression in defined neuronal populations. We present a Gateway(R)-based cloning platform providing a robust pipeline for rapid, efficient construction of recombinant adeno-associated virus (rAAV) vectors optimized for neuroscience applications. This platform addresses promoter selection, indicator engineering, and capsid-type optimization, and enables systematic optimization of vector components across a range of optical tools. The benefit of this modular approach is illustrated in the case of ULoVE, a two-photon microscopy method based on acousto-optic deflectors (AODs). This method provides serial light-targeting with kHz sampling rates and high signal-to-noise ratio in vivo, which imposes stringent requirements on indicator expression -- including cell-type specificity, sparse labelling, and precise control of expression levels-- efficiently met through the combinatorial flexibility of the Gateway pipeline. As specific examples, Gateway-constructed Cre-driver viruses combined with Cre-dependent reporters enabled cell-type-specific labelling for two complementary applications. In cerebellar Purkinje cells, an L7::Cre driver virus paired with a Gateway-constructed voltage indicator (JEDI2P-Kv) and ULoVE two-photon excitation at ~5 kHz enables resolution of sub-millisecond dendritic voltage dynamics in awake, behaving mice, including optical detection of dendritic spikelets previously accessible only via intracellular electrophysiology. The same driver virus paired with calcium indicators (GCaMP6f, jRGECO1a) resolves climbing fiber-evoked calcium kinetics under the same conditions. In acute cerebellar slices, a kit::Cre driver virus enabled cell-type-specific expression of the optogenetic actuator ChR2(H134R) in molecular layer interneurons, where ULoVE doughnut-pattern photostimulation achieved single-cell, sub-millisecond optogenetic activation with micron-scale spatial resolution. Beyond ULoVE applications, the same sparse, strong labelling also proved suitable for anatomical tracing of axonal projections in cleared cerebellar tissue, resolving individual DCN axon terminals at the granule cell layer --molecular layer boundary. Taken together, our dual-front approach --combining a modular AAV expression pipeline with AOD-based optical acquisition --provides an integrated platform for developing sophisticated optical tools, including but not limited to AOD-based microscopy, for neural circuit interrogation.

neuroscience↗

A red-emitting, genetically encoded indicator for two-photon voltage recording in vivo

Genetically encoded voltage indicators (GEVIs) enable minimally invasive, cell-type-specific optical measurements of neuronal membrane potential with millisecond temporal resolution. Red-shifted GEVIs are especially advantageous because they permit spectral multiplexing with complementary sensors and enable all-optical circuit interrogation in combination with blue-light-activated opsins. Despite these advantages, existing red GEVIs remain poorly suited for in vivo use due to limited performance under two-photon (2P) excitation, the predominant modality for deep-tissue imaging. Here, we introduce VADER1, a red GEVI that overcomes this limitation and enables reliable spike detection in vivo under 2P illumination. Under 2P excitation, VADER1 supports extended voltage imaging with both random-access and resonant-scanning microscopy, enables recordings from neurons as deep as cortical layer 5, and allows dual-color imaging with calcium indicators. By filling a critical spectral gap, VADER1 enables integrated optical measurements of fast electrical activity alongside other neural signals and establishes a foundation for two-photon all-optical electrophysiology.

neuroscience↗

Designer indicators for two-photon recording of subthreshold voltage dynamics

Subthreshold voltage dynamics are critical for neuronal information integration, yet they remain understudied in vivo due to the limitations of current tools. While genetically encoded voltage indicators (GEVIs) offer a promising alternative, their application for deep-tissue recording using two-photon (2P) microscopy--a preferred method for deep-tissue recording--has been hindered by insufficient sensitivity for detecting millivolt-scale subthreshold signals. Here, we refined our multiparametric two-photon high-throughput screening platform to develop two novel GEVIs, JEDI3sub and JEDI3hyp, tailored explicitly for subthreshold voltage detection. Through fast 2P optical recording in awake, behaving mice, we demonstrated the superior sensitivity of JEDI3 indicators compared to JEDI-2P. We also showed that JEDI3sub can track population-level subthreshold optical tuning, while JEDI3hyp reliably captured subthreshold dynamics associated with sharp-wave ripple oscillations in hippocampal PV interneurons. Finally, JEDI3hyp facilitated extended imaging of brain-state-dependent, millivolt-scale subthreshold voltage changes across deep-layer somas, fine dendritic structures, and diverse cell types. By addressing the critical gap in 2P optical recording of subthreshold voltage dynamics, JEDI3 indicators open new avenues for studying neural information processing and its alterations in health and disease.

neuroscience↗

A versatile, positive-going voltage indicator that enables accessible two-photon recordings in vivo

Genetically encoded voltage indicators (GEVIs) enable cell-type-specific optical readout of membrane potential, but two-photon (2P) spike detection has been hampered by low signal-to-noise and ultrafast off-kinetics, restricting use to specialized microscopes. We introduce FORCE1s, a green, positive-going GEVI engineered to make robust 2P voltage imaging broadly accessible. FORCE1s brightens from a dark baseline during depolarization, reports spikes with [~]100% {Delta}F/F in awake mice, and displays repolarization kinetics that are tuned for reliable spike detection at sub-kilohertz frame rates. As a result, FORCE1s supports spike-resolved multi-cell recordings on standard resonant-scanning microscopes, and further scales to larger fields of view and neuron counts on advanced modalities. FORCE1s also enables multiplexed voltage-neurotransmitter imaging and extended recordings in freely moving mice using a compact, affordable MEMS-based 2P miniscope. Together, these advances establish FORCE1s as a community-ready tool that democratizes deep-tissue voltage imaging across platforms and experimental contexts.

neuroscience↗

Temporal Focusing for Enhanced Background Rejection in AOD-Based Two-Photon Serial Holography

The ability to record 3D neuronal activity with cellular resolution, high signal-to-noise ratio (SNR) and millisecond temporal resolution is a major challenge in neuroscience. One powerful method is random-access two-photon microscopy based on acousto-optic deflectors (AODs), which uses a holographically-shaped point spread function (PSF) scanned in 3D to maximize the sampling rate and SNR. However, this approach suffers from greater background contamination due to the holographically shaped PSF than standard two-photon microscopy with diffraction-limited PSF. To overcome this limitation, we implemented a new version of an AOD scanning system, which integrates temporal focusing. The complex spatiotemporal distortions encountered in this configuration, including a significant group delay dispersion associated with the pulse front tilt generated by the AOD, were compensated for by introducing an acousto-optic modulator before the AOD. We designed extended patterns by combining temporal focusing on one direction and holographic wavefront shaping in the perpendicular axis. Taking advantage of the AODs ability to shape the wavefront at the same speed as the scan, we were able to accurately superimpose the spatial and temporal foci over the entire field of view. Finally, we generated complex, extended two-photon excitation patterns by combining temporal focusing in one direction and holographic multiplexing in the perpendicular direction. These patterns provide significantly improved background rejection compared to 2D holographic patterns, thus offering promising prospects for in vivo recordings of neuronal activity in dense samples with improved SNR.

biophysics↗

Fast wavefront shaping for two-photon brain imaging with large field of view correction

Introduction paragraphIn-vivo optical imaging with diffraction-limited resolution deep inside scattering biological tissues is obtained by non-linear fluorescence microscopy1. Active compensation of tissue-induced aberrations and light scattering through adaptive wavefront correction2,3 further extends depth penetration by restoring high resolution at large depth. However, at large depths those corrections are only valid over a very limited field of view within the angular memory effect4. To overcome this limitation, we introduce an acousto-optic light modulation technique for fluorescence imaging with simultaneous wavefront correction at pixel scan speed. Biaxial wavefront corrections are first learned by adaptive optimization at multiple locations in the image field. During image acquisition, the learned corrections are then switched on-the-fly according to the position of the excitation focus during the raster scan. The proposed microscope is applied to in-vivo transcranial neuron imaging and demonstrates correction of skull-induced aberrations and scattering across large fields of view at 40 kHz data acquisition speed.

neuroscience↗