Search bioRxiv⌕ Search

Biology subjects

Bonelli, F.

Publications and source records attributed to Bonelli, F..

2 recordsLinked to original sources

Clinical And Analytical Performance Of An Automated Serological Test That Identifies S1/S2 Neutralizing IgG In Covid-19 Patients Semiquantitatively.

BACKGROUNDIn the Covid-19 pandemic, highly selective serological testing is essential to define exposure to SARS-CoV-2 virus. Many tests have been developed, yet with variable speed to first result, and of unknown quality, particularly when considering the prediction of neutralizing capacity. OBJECTIVES/METHODSThe LIAISON(R) SARS-CoV-2 S1/S2 IgG assay was designed to measure antibodies against the SARS-CoV-2 native S1/S2 proteins in a standardized automated chemiluminescent assay. Clinical and analytical performance of the test were validated in an observational study using residual samples (>1500) with positive or negative Covid-19 diagnosis. RESULTSThe LIAISON(R) SARS-CoV-2 S1/S2 IgG assay proved highly selective and specific, and offers semiquantitative measures of serum or plasma levels of anti-S1/S2 IgG with neutralizing activity. The diagnostic sensitivity was 91.3% and 95.7% at >5 or [&ge;]15 days from diagnosis respectively, and 100% when assessed against a neutralizing assay. The specificity ranged between 97% and 98.5%. The average imprecision of the assay was <5 % coefficient of variation. Assay performance at 2 different cut-offs was evaluated to optimize predictive values in settings with different % disease prevalence. CONCLUSIONS. The automated LIAISON(R) SARS-CoV-2 S1/S2 IgG assay brings efficient, sensitive, specific, and precise serological testing to the laboratory, with the capacity to test large amounts of samples per day: first results are available within 35 minutes with a throughput of 170 tests/hour. The test also provides a semiquantitative measure to identify samples with neutralizing antibodies, useful also for a large scale screening of convalescent plasma for safe therapeutic use. IMPORTANCEWith the worldwide advance of the COVID-19 pandemic, efficient, reliable and accessible diagnostic tools are needed to support public health officials and healthcare providers in their efforts to deliver optimal medical care, and articulate sound demographic policy. DiaSorin has developed an automated serology based assay for the measurement of IgG specific to SARS CoV-2 Spike protein, and tested its clinical performance in collaboration with Italian health care professionals who provided access to large numbers of samples from infected and non-infected individuals. The assay delivers excellent sensitivity and specificity, and is able to identify samples with high levels of neutralizing antibodies. This will provide guidance in assessing the true immune status of subjects, as well as meeting the pressing need to screen donors for high titer convalescent sera for subsequent therapeutic and prophylactic use.

immunology↗

Determination of salivary cortisol in donkey stallions

Salivary cortisol provides information about free plasma cortisol concentration and salivary sampling is a non-invasive well-tolerate procedure. The aim of this study was to validate a commercial enzyme immunoassay for the determination of salivary cortisol in donkeys.\n\nSaliva samples were collected in 4 donkey stallions on thirteen non-consecutive days at 8:30 AM to avoid circadian variation. Animals were already accustomed to be handled. Saliva was collected by using a swab inserted at the angle of the lips, placed onto the tongue for 1 min and returned into a polypropylene tube. Tubes were centrifuged and at least 1 ml of saliva was aspirated from each sample and frozen at -20{degrees} C until analysis. A commercial enzyme immunoassay kit without extraction was used for determination of cortisol in saliva. Median cortisol concentrations with minimum and maximum value were calculated.\n\nRecovery of cortisol standard in donkey saliva was 107.9% and serial dilution of donkey saliva samples with assay buffer resulted in changes in optical density parallel to the standard curve. Cross-reactivity of the antiserum was 10.4% with 11-deoxycortisol, 5.2% with corticosterone, 0.4% with 11-deoxycorticosterone, 0.2% with cortisone and <0.1% with testosterone, progesterone and estradiol. The intra-assay coefficient of variation was 10.7%, the inter-assay variation was 8.0% and the minimal detectable concentration was 0.01 ng/ml.\n\nThe results of the present study demonstrate the validity of a commercial kit to determine the concentration of cortisol in donkey saliva, as already reported in other species.

physiology↗