Search bioRxiv⌕ Search

Biology subjects

Blazeski, A.

Publications and source records attributed to Blazeski, A..

4 recordsLinked to original sources

Remodeling of self-assembled microvascular networks under long term flow

The incorporation of a functional perfusable microvascular network (MVN) is a common requirement for most organ on-chip-models. Long-term perfusion of MVNs is often required for the maturation of organ phenotypes and disease pathologies and to model the transport of cells and drugs entering organs. In our microphysiological system, we observe that flow can recover perfusion in regressed MVNs and maintain perfusable MVNs for at least 51 days. Throughout the 51 days, however, the MVNs are continuously remodeling to align with the direction of bulk flow and only appear to attain morphological homeostasis with the use of maintenance medium without growth factors. We observed that the flow resistance of the MVNs decreases over time, and using a computational model, we show that stable vessels have higher flow rates and velocities compared to regressing vessels. Cytokine analysis suggests that static conditions generate an inflammatory state, and that continuous flow reduces inflammation over an extended period. Finally, through bulk RNA sequencing we identify that both the endothelial and fibroblast cells are actively engaged in vascular and matrix remodeling due to flow and that these effects persist for at least 2 weeks. This MPS can be applied to study hemodynamically driven processes, such as metastatic dissemination or drug distribution, or to model long-term diseases previously not captured by MPS, such as chronic inflammation or aging-associated diseases.

biophysics↗

Myofibroblasts reduce angiogenesis and vasculogenesis in a vascularized microphysiological model of lung fibrosis

Lung fibrosis, characterized by chronic and progressive scarring, has no cure. Hallmarks are the accumulation of myofibroblasts and extracellular matrix, as well as vascular remodeling. The crosstalk between myofibroblasts and vasculature is poorly understood, with conflicting reports on whether angiogenesis and vessel density are increased or decreased in lung fibrosis. We developed a microphysiological system that recapitulates the pathophysiology of lung fibrosis and disentangles myofibroblast-vascular interactions. Lung myofibroblasts maintained their phenotype in 3D without exogenous TGF-{beta} and displayed anti-angiogenic and anti-vasculogenic activities when cultured with endothelial cells in a microfluidic device. These effects, including decreased endothelial sprouting, altered vascular morphology, and increased vascular permeability, were mediated by increased TGF-{beta}1 and reduced VEGF secretion. Pharmacological interventions targeting these cytokines restored vascular morphology and permeability, demonstrating the potential of this model to screen anti-fibrotic drugs. This system provides insights into myofibroblast-vascular crosstalk in lung fibrosis and offers a platform for therapeutic development.

bioengineering↗

Plxnd1-mediated mechanosensing of blood flow controls the caliber of the Dorsal Aorta via the transcription factor Klf2

The cardiovascular system generates and responds to mechanical forces. The heartbeat pumps blood through a network of vascular tubes, which adjust their caliber in response to the hemodynamic environment. However, how endothelial cells in the developing vascular system integrate inputs from circulatory forces into signaling pathways to define vessel caliber is poorly understood. Using vertebrate embryos and in vitro-assembled microvascular networks of human endothelial cells as models, flow and genetic manipulations, and custom software, we reveal that Plexin-D1, an endothelial Semaphorin receptor critical for angiogenic guidance, employs its mechanosensing activity to serve as a crucial positive regulator of the Dorsal Aortas (DA) caliber. We also uncover that the flow-responsive transcription factor KLF2 acts as a paramount mechanosensitive effector of Plexin-D1 that enlarges endothelial cells to widen the vessel. These findings illuminate the molecular and cellular mechanisms orchestrating the interplay between cardiovascular development and hemodynamic forces. HighlightsO_LIPlexin-D1 mechanosensing of blood flow tunes the caliber of the Dorsal Aorta (DA) C_LIO_LIThe DA widens without raising endothelial cell numbers, which can change separate from the caliber C_LIO_LIThe Kruppel-like transcription factor 2 (KLF2) is a key Plexin-D1 mechano-effector during development C_LIO_LIKLF2 increases endothelial cell size to expand the DA caliber C_LI

developmental biology↗

Engineering microvascular networks using a KLF2 reporter to probe flow-dependent endothelial cell function

Shear stress generated by the flow of blood in the vasculature is a potent regulator of endothelial cell phenotype and vascular structure. While vascular responses to flow are complex and context-dependent, endothelial cell signaling in response to shear stress induced by laminar flows is coordinated by the transcription factor KLF2. The expression of KLF2 in endothelial cells is associated with a quiescent, anti-inflammatory phenotype and has been well characterized in two-dimensional systems, but has not been studied in three-dimensional in vitro systems. Here we develop engineered microvascular networks (MVNs) with a KLF2-based endothelial cell sensor within a microfluidic chip, apply continuous flow using an attached microfluidic pump, and study the effects of this flow on vascular structure and function. We found that culture of MVNs exposed to flow for 48 hours that resulted in increased expression of the KLF2-GFP-reporter display larger vessel diameters and decreased vascular branching and resistance. Additionally, vessel diameters after the application of flow were independent of initial MVN morphologies. Finally, we found that MVNs exposed to flow have improved vascular barrier function and decreased platelet adhesion. The MVNs with KLF2-based flow sensors represent a powerful tool for evaluating the structural and functional effects of flow on engineered three-dimensional vascular systems.

bioengineering↗