Post-translational modifications (PTMs) are chemical changes added to proteins after translation. These changes affect protein function and regulation, and their disruption is linked to disease-associated mechanisms. Because experimentally validating all possible modification sites is impractical, many computational predictors have been developed for PTM site prediction. In this work, we study whether a shared model can represent common residue-background patterns while learning modification-specific background-to-positive offsets. This framing is especially relevant for residues such as lysine (K), which can be acetylated, ubiquitinated, methylated, or sumoylated depending on the surrounding protein context. We propose an anchor-guided rectified flow matching framework for multi-type PTM site prediction from protein language model embeddings. For each PTM--residue pair, the model builds residue-background anchors from PTM-compatible unannotated residues and positive anchors from experimentally annotated modified residues. Given a candidate residue and target modification type, the model compares the residue embedding with these anchor sets and uses a rectified flow module to estimate a modification-conditioned background-to-positive offset. This offset is combined with anchor-based features and used for site scoring. We evaluate the framework on a dbPTM-derived benchmark covering six commonly studied PTMs: phosphorylation, acetylation, ubiquitination, methylation, sumoylation, and N-linked glycosylation. In the shared-model setting, our approach achieves a macro AUPRC of 0.4195, improving over the gated multi-anchor baseline of 0.4154, while independently trained per-modification models achieve 0.4353. These results suggest that multi-type PTM prediction can be modeled within a single shared framework by combining residue-background anchors with modification-conditioned offset features.

bioinformatics↗

Cumulative Transfer Function for Assessment of MRI-Induced RF Heating Risk in Pediatric Patients Implanted with Bifurcated Leads

PurposeRF-induced heating remains a major barrier to MRI access for patients with epicardial cardiac implantable electronic devices (CIEDs). Although ISO/TS 10974 Tier-3 transfer function (TF) methods are established for unbranched leads, no analogous framework exists for bifurcated leads, in which branch asymmetry and inter-branch coupling may substantially alter heating. We developed and validated a cumulative transfer function (cTF) framework to address this gap. MethodsFollowing ISO/TS 10974 Tier-3 formalism, we measured, calibrated, and validated cTFs for a commercial 35 cm bipolar epicardial lead at 1.5 T. The framework explicitly accounts for branch-specific response and cross-branch coupling. Validation was performed with 24 canonical lead configurations in a homogeneous phantom and, without recalibration, in a heterogeneous anthropomorphic pediatric phantom with clinically derived trajectories. A single-branch TF approximation served as a comparator. The validated cTF was applied to predict RF heating across adult and pediatric human models at multiple imaging landmarks. ResultsCompared with the single-branch TF approximation, the cTF reduced prediction error by nearly 70% in the primary validation dataset. In secondary validation, the cTF maintained low error across clinically relevant trajectories and imaging landmarks. In human models, the framework revealed marked anatomy- and landmark-dependent variation in predicted heating for the tested 35 cm lead, with low predicted heating in pediatric models and substantially higher heating in selected adult chest and upper abdominal imaging scenarios. ConclusionThe cTF provides a validated framework for RF-heating assessment of bifurcated leads and substantially improves prediction accuracy over single-branch TF approximations that neglect branch coupling.

bioengineering↗

RF Heating of Bipolar Epicardial Implants during MRI at 0.55 T and 1.5T: Effect of Device Length and Termination Conditions

Pediatric patients with epicardial cardiac implantable electronic devices (CIEDs) are frequently excluded from the Magnetic Resonance Imaging (MRI) primarily due to RF heating safety concerns. In this study we evaluate RF heating of two bipolar epicardial leads during MRI at 0.55 T and 1.5 T under different termination conditions. Our findings showed that the mean RF heating was significantly reduced at 0.55 T MRI compared to that at 1.5 T. Similarly, the RF heating at 0.55 T MRI was highest for full system whereas, during MRI at 1.5 T, the RF heating was highest for the capped abandoned lead, showing dependence of RF heating pattern on MRI field strength. While RF heating at both fields surpassed the safety limit, the capped abandoned leads at 1.5 T MRI showed significantly higher RF heating with temperature rise surpassing 50{degrees}C in some of the cases. These results highlight the difference in RF heating of bipolar epicardial leads compared to the previously reported findings for monopolar epicardial lead which showed smallest heating for capped abandoned lead at both field strengths. These findings emphasize the necessity of device-specific evaluations at each field-strength to inform clinical decision-making and expand MRI access for this vulnerable population.

biophysics↗

Age and lead configuration matter: A comparative study of RF-induced heating of epicardial and endocardial electronic devices in adult and pediatric anthropomorphic phantoms in 1.5 T MR

BackgroundChildren with congenital heart defects often have life-sustaining indications for a cardiac implantable electronic device (CIED). In children, these devices are typically sewn to the heart epicardium, but the FDA has never licensed an epicardial system as MR-Conditional due to limited data. Childrens hospitals default to either refusing MRI service to a vast majority of pediatric CIED patients or adopting a scan-all strategy based on results from adult studies. We argue that both approaches are flawed, and the risk-benefit decisions should be made on an individual basis. PurposeTo provide evidence-based knowledge on RF-induced heating of CIEDs in children and adults with epicardial and endocardial leads of different lengths. Study TypePhantom Field Strength/Sequence1.5 T. Assessment120 clinically relevant epicardial and endocardial device configurations were implemented in adult and pediatric anthropomorphic phantoms. Temperature rise was recorded during RF exposure at 1.5 T. Statistical TestsMeans comparisons were implemented using two-sample t-tests, reliability analysis using interclass correlation coefficient based on a single rating, absolute-agreement, 2-way mixed-effects model. ResultsThere was significantly higher RF heating of epicardial leads compared to endocardial leads in the pediatric phantom (3.4 {+/-} 3.0 vs. 0.6 {+/-} 0.4 {degrees}C, p<0.001); however, there was no significant difference in the adult phantom (3.0 {+/-} 3.2 vs. 2.0 {+/-} 1.8, p=0.16). Endocardial leads in the pediatric phantom generated significantly less RF heating than in the adult phantom (0.6 {+/-} 0.4 {degrees}C vs. 2.0 {+/-} 1.8 {degrees}C, p<0.001). Data ConclusionBody size and lead length significantly affected RF heating. For models based on younger children with short epicardial leads (e.g., 25cm), RF heating up to 12 {degrees}C was observed, delivering a cumulative thermal dose previously associated with tissue necrosis. In contrast, RF heating in model based on children with endocardial leads was well below the heating expected from physiologic fever (3 {degrees}C).

biophysics↗

Modifying the trajectory of epicardial leads can substantially reduce MRI-induced RF heating in pediatric patients with a cardiac implantable electronic device

PurposeInfants and children with congenital heart defects, inherited arrhythmia syndromes, and congenital cardiac conduction disorders often receive epicardial implantable electronic devices. Unfortunately, once an epicardial device is implanted, the patient is no longer eligible to receive MRI exams due to an elevated risk of RF heating. Here we show that a simple modification in the trajectory of epicardial leads can substantially and reliably reduce RF heating during MRI at 1.5 T, with benefits extending to abandoned leads. MethodsElectromagnetic simulations were performed to assess RF heating of two common epicardial lead trajectories exhibiting different degrees of coupling with MRI incident electric fields. Experiments in anthropomorphic phantoms implanted with commercial cardiac implantable electronic devices (CIEDs) confirmed the findings. ResultsSimulations of an epicardial lead with a trajectory where the excess length of the lead was looped and placed on the anterior surface of the heart showed a 9-fold reduction in 0.1g-averaged SAR compared to the lead with excess length looped on the inferior surface of the heart. Repeated experiments with a commercial epicardial device confirmed the results, showing a 16-fold reduction in the average temperature rise for fully implanted systems with leads following low-SAR trajectories, and a 20-fold reduction in RF heating on an abandoned lead. ConclusionSurgical modification of epicardial lead trajectory can substantially reduce RF heating at 1.5 T, with benefits extending to abandoned leads.

biophysics↗

Artifacts can be deceiving: The actual location of deep brain stimulation electrodes differs from the artifact seen on magnetic resonance images

IntroductionDeep brain stimulation (DBS) is a common treatment for a variety of neurological and psychiatric disorders. Recent studies have highlighted the role of neuroimaging in localizing the position of electrode contacts relative to target brain areas in order to optimize DBS programming. Among different imaging methods, postoperative magnetic resonance imaging (MRI) has been widely used for DBS electrode localization; however, the geometrical distortion induced by the lead limits its accuracy. In this work, we investigated to what degree the difference between the actual location of the leads tip and the location of the tip estimated from the MRI artifact varies depending on the MRI sequence parameters such as acquisition plane and phase encoding direction, as well as the leads extracranial configuration. Accordingly, an imaging technique to increase the accuracy of lead localization was devised and discussed. MethodsWe designed and constructed an anthropomorphic phantom with an implanted DBS system following 18 clinically relevant configurations. The phantom was scanned at a Siemens 1.5 Tesla Aera scanner using a T1MPRAGE sequence optimized for clinical use and a T1TSE sequence optimized for research purposes. We varied slice acquisition plane and phase encoding direction and calculated the distance between the caudal tip of the DBS lead MRI artifact and the actual tip of the lead, as estimated from MRI reference markers. ResultsImaging parameters and lead configuration substantially altered the difference in the depth of the lead within its MRI artifact on the scale of several millimeters - with a difference as large as 4.99 millimeters. The actual tip of the DBS lead was found to be consistently more rostral than the tip estimated from the MR image artifact. The smallest difference between the tip of the DBS lead and the tip of the MRI artifact using the clinically relevant sequence (i.e., T1MPRAGE) was found with the sagittal acquisition plane and anterior-posterior phase encoding direction. Discussion/ConclusionThe actual tip of an implanted DBS lead is located up to several millimeters rostral to the tip of the leads artifact on postoperative MR images. This distance depends on the MRI sequence parameters and the DBS systems extracranial trajectory. MRI parameters may be altered to improve this localization.

neuroscience↗

Efficient Fluorescence-Based Localization Technique for Tracking Endophytes Route in Host-Plants Colonization

Bacterial isolates that enhance plant growth and suppress plant pathogens growth are essential tools for reducing pesticide applications in plant production systems. The objectives of this study were to develop a reliable fluorescence-based technique for labeling bacterial isolates selected as biological control agents (BCAs) to allow their direct tracking in the host-plant interactions, understand the BCA localization within their host plants, and the route of plant colonization. Objectives were achieved by developing competent BCAs transformed with two plasmids, pBSU101 and pANIC-10A, containing reporter genes eGFP and pporRFP, respectively. Our results revealed that the plasmid-mediated transformation efficiencies of antibiotic-resistant competent BCAs identified as PSL, IMC8, and PS were up 84%. Fluorescent BCA-tagged reporter genes were associated with roots and hypocotyls but not with leaves or stems and were confirmed by fluoresence microscopy and PCR analyses in colonized Arabidopsis and sorghum. This fluorescence-based techniques high resolution and reproducibility make it a platform-independent system that allows tracking of BCAs spatially within plant tissues, enabling assessment of the movement and niches of BCAs within colonized plants. Steps for producing and transforming competent fluorescent BCAs, as well as the inoculation of plants with transformed BCAs, localization, and confirmation of fluorescent BCAs through fluorescence imaging and PCR, are provided in this manuscript. This study features host-plant interactions and subsequently biological and physiological mechanisms implicated in these interactions. The maximum time to complete all the steps of this protocol is approximately three months. SENTENCE SUMMARYWe describe a novel fluorescence localization technique as a powerful tool to directly visualize and determine the route in-situ of BCAs in host-plants interaction. The study features the host-plant interactions, biological and physiological responses implicated.

cell biology↗

Application of Surgical Lead Management and Reconfigurable Coil Technology to Reduce RF Heating of DBS Implants during MRI at 3T Under Variant Body Compositions

Patients with active implants such as deep brain stimulation (DBS) devices, have limited access to magnetic resonance imaging (MRI) due to risks of RF heating. With an aging population, the prevalence of neurodegenerative and vascular disease increases; and so does the indication for MRI exams in patients with such implants. In response to this growing need for MRI, many groups have investigated strategies to mitigate the RF heating of the implants. These efforts, however, have relied either on simulations with homogenous body models or simplified phantom experiments (box shaped phantom with single tissue). It is well established, however, that the shape and heterogeneity of human body affects the distribution of MRI electric fields, which by proxy, alters the RF heating of an implant inside the body. In this contribution, we applied numerical simulations and phantom experiments to examine the effectiveness of RF heating mitigation strategies under variant patient body compositions, focusing on two recently proposed techniques: (a) surgical modification of DBS lead trajectories inside the body, and (b) use of a patient-adjustable reconfigurable MRI coil, both aiming to reduce the coupling of implanted leads and MRI electric fields. Our results demonstrated that both techniques perform well under variant body compositions.Competing Interest StatementThe authors have declared no competing interest.View Full Text

bioengineering↗

The effect of device configuration and patient body composition on image artifact and RF heating of deep brain stimulation devices during MRI at 1.5T and 3T

BACKGROUNDPatients with deep brain stimulation (DBS) implants have limited access to MRI due to safety concerns associated with RF-induced heating. Currently, MRI in these patients is allowed only in 1.5T horizontal scanners and with pulse sequences with reduced power. Nevertheless, off-label use of MRI at 3T is increasingly reported based on limited safety assessments. Here we present results of systematic RF heating measurements for two commercially available DBS systems during MRI at 1.5T and 3T. PURPOSETo assess the effect of imaging landmark, DBS lead configuration, and patient body composition on RF heating of DBS leads during MRI at 1.5 T and 3T. STUDY TYPEPhantom study. POPULATION/SUBJECTS/PHANTOM/SPECIMEN/ANIMAL MODELGel phantoms and cadaver brain. FIELD STRENGTH/SEQUENCE1.5T and 3T, T1-weighted turbo spin echo. ASSESSMENTRF heating was measured at tips of DBS leads implanted in brain-mimicking gel. STATISTICAL TESTSNone. RESULTSWe observed substantial fluctuation in RF heating mainly affected by phantom composition and DBS lead configuration, ranging from 0.14{degrees}C to 23.73{degrees}C at 1.5 T, and from 0.10{degrees}C to 7.39{degrees}C at 3T. The presence of subcutaneous fat substantially altered RF heating at electrode tips (-3.06{degrees}C < {Delta}T < 19.05{degrees}C). Introducing concentric loops in the extracranial portion of the lead at the surgical burr hole reduced RF heating by up to 89% at 1.5T and up to 98% at 3T compared to worst case heating scenarios. DATA CONCLUSIONDevice configuration and patient body composition significantly altered the RF heating of DBS leads during MRI at 1.5T and 3T. Interestingly, certain lead trajectories consistently reduced RF heating and image artifact over different imaging landmarks, RF frequencies, and phantom compositions. Such trajectories could be implemented in patients with minimal disruption to the surgical workflow.

bioengineering↗