Inter-user comparison for quantification of superparamagnetic iron oxides with magnetic particle imaging across two institutions highlights a need for standardized approaches

PurposeMagnetic particle imaging (MPI) is being explored in biological contexts that require accurate and reproducible quantification of superparamagnetic iron oxide nanoparticles (SPIONs). While many groups have focused on improving imager and SPION design to improve resolution and sensitivity, few have focused on improving quantification and reproducibility of MPI. The aim of this study was to compare MPI quantification results by two different systems and the accuracy of SPION quantification performed by multiple users at two institutions. ProceduresSix users (3 from each institute) imaged a known amount of Vivotrax+ (10 g Fe), diluted in a small (10 L) or large (500 L) volume. These samples were imaged with or without calibration standards in the field of view, to create a total of 72 images (6 users x triplicate samples x 2 sample volumes x 2 calibration methods). These images were analyzed by the respective user with two region of interest (ROI) selection methods. Image intensities, Vivotrax+ quantification, and ROI selection was compared across users, within and across institutions. ResultsMPI imagers at two different institutes produce significantly different signal intensities, that differ by over 3 times for the same concentration of Vivotrax+. Overall quantification yielded measurements that were within {+/-} 20% from ground truth, however SPION quantification values obtained at each laboratory were significantly different. Results suggest that the use of different imagers had a stronger influence on SPION quantification compared to differences arising from user error. Lastly, calibration conducted from samples in the imaging field of view gave the same quantification results as separately imaged samples. ConclusionsThis study highlights that there are many factors that contribute to the accuracy and reproducibility of MPI quantification, including variation between MPI imagers and users, despite pre-defined experimental set up, image acquisition parameters, and ROI selection analysis.

biophysics↗

MPI region of interest (ROI) analysis and quantification of iron in different volumes

MPI directly detects superparamagnetic iron oxides (SPIONs), which should enable precise, accurate, and linear quantification. However, selecting a region of interest (ROI) has strong effects on MPI quantification results. Ideally, ROI selection should be simple, user-independent, and widely applicable. In this work, we describe and compare four MPI ROI selection methods and assess their performance in vitro and in vivo. To explore the effect of ROI selection, ten ferucarbotran phantoms were imaged, each contained the same amount of iron but varied in volume. Three users tested the accuracy of the ROI methods for quantification of these samples. Lastly, the four ROI methods were applied to quantify ferucarbotran in vivo after intravenous, intramuscular, and subcutaneous injections in mice. We demonstrate that each ROI method has strengths. We conclude there is an important trade-off between ROI size and the accuracy of iron quantification, therefore the choice of ROI selection method for each study must be carefully informed.

biophysics↗