Search bioRxiv⌕ Search

Biology subjects

Bendele, N.

Publications and source records attributed to Bendele, N..

2 recordsLinked to original sources

3D Tumor-Mimicking Phantom Models for Assessing NIR I/II Nanoparticles in Fluorescence-Guided Surgical Interventions

Fluorescence image-guided surgery (FIGS) offers high spatial resolution and real-time feedback but is limited by shallow tissue penetration and autofluorescence from current clinically approved fluorophores. The near-infrared (NIR) spectrum, specifically the NIR-I (700-900 nm) and NIR-II (950-1700 nm), addresses these limitations with deeper tissue penetration and improved signal-to-noise ratios. However, biological barriers and suboptimal optical performance under surgical conditions have hindered the clinical translation of NIR-I/II nanoprobes. In vivo mouse models have shown promise, but these models do not replicate the complex optical scenarios encountered during real-world surgeries. Existing tissue-mimicking phantoms used to evaluate NIR-I/II imaging systems are useful but fall short when assessing nanoprobes in surgical environments. These phantoms often fail to replicate the tumor microenvironment, limiting their predictive assessment. To overcome these challenges, we propose developing tumor-mimicking phantom models (TMPs) that integrate key tumor features, such as tunable tumor cell densities, in vivo-like nanoparticle concentrations, biologically relevant factors (pH, enzymes), replicate light absorption components (hemoglobin), and light scattering components (intralipid). These TMPs enable more clinically relevant assessments of NIR-I/II nanoprobes, including optical tissue penetration profiling, tumor margin delineation, and ex vivo thoracic surgery on porcine lungs. The components of TMPs can be further modulated to closely match the optical profiles of in vivo and ex vivo tumors. Additionally, 3D bioprinting technology facilitates a high-throughput platform for screening nanoprobes under realistic conditions. This approach will identify high-performing NIR-I/II probes with superior surgical utility, bridging the gap between preclinical findings and clinical applications, and ensuring results extend beyond traditional in vivo mouse studies. TOC O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=46 SRC="FIGDIR/small/636085v2_ufig1.gif" ALT="Figure 1"> View larger version (16K): org.highwire.dtl.DTLVardef@12b283aorg.highwire.dtl.DTLVardef@5e2dc7org.highwire.dtl.DTLVardef@10f6c36org.highwire.dtl.DTLVardef@189590d_HPS_FORMAT_FIGEXP M_FIG C_FIG

bioengineering↗

Near-Infrared Afterglow Luminescence Amplification via Albumin Complexation of Semiconducting Polymer Nanoparticles for Surgical Navigation in Ex Vivo Porcine Models

Afterglow imaging, leveraging persistent luminescence following light cessation, has emerged as a promising modality for surgical interventions. However, the scarcity of efficient near-infrared (NIR) responsive afterglow materials, along with their inherently low brightness and lack of cyclic modulation in afterglow emission, has impeded their widespread adoption. Addressing these challenges requires a strategic repurposing of afterglow materials that improve on such limitations. Here, we have developed an afterglow probe, composed of bovine serum albumin (BSA) coated with an afterglow material, a semiconducting polymer dye (PFODBT/SP1), called BSA@SP1 demonstrating a substantial amplification of the afterglow luminescence ([~]3-fold) compared to polymer-lipid coated PFODBT (DSPE-PEG@SP1) under same experimental conditions. This enhancement is believed to be attributed to the electron-rich matrix provided by BSA that immobilizes SP1 and enhances the generation of 1O2 radicals, which improves the afterglow luminescence brightness. Through molecule docking, physicochemical characterization, and optical assessments, we highlight BSA@SP1s superior afterglow properties, cyclic afterglow behavior, long-term colloidal stability, and biocompatibility. Furthermore, we demonstrate superior tissue permeation profiling of afterglow signals of BSA@SP1s compared to fluorescence signals using ex vivo tumor-mimicking phantoms and various porcine tissue types (skin, muscle, and fat). Expanding on this, to showcase BSA@SP1s potential in image-guided surgeries, we implanted tumor-mimicking phantoms within porcine lungs and conducted direct comparisons between fluorescence and afterglow-guided interventions to illustrate the latters superiority. Overall, our study introduces a promising strategy for enhancing current afterglow materials through protein complexation, resulting in both ultrahigh signal-to-background ratios and cyclic afterglow signals.

bioengineering↗