Search bioRxiv⌕ Search

Biology subjects

Baxter, J. R.

Publications and source records attributed to Baxter, J. R..

At least 19 recordsLinked to original sources

Impaired loading following denervation elicits dynamic, differential growth trajectories of musculoskeletal tissues

Physical forces dictate the function and maintenance of adult musculoskeletal tissues. Yet, the impact of biophysical cues on the growth and maturation of these tissues, especially dense connective tissues, remains unclear. Here, we investigated the effects of neonatal mechanical loading on early postnatal growth of the musculoskeletal tissues of the lower limb, with particular focus on the Achilles tendon. We performed sciatic nerve resection (SNR) on one-day-old mice to denervate the hamstrings and distal hindlimb muscles. Sciatic Nerve Resection resulted in severe and sustained alterations in gait, accompanied by an altered transcriptional landscape in distal musculoskeletal tissues, with marked reductions in bone and tendon growth and smaller, fibrotic hindlimb musculature. Sciatic nerve resection impaired cumulative growth in the Achilles tendon, shifting cell proliferation and matrix-driven growth trajectories and altering mechanotransduction gene programs toward inflammation and matrix catabolism with age. This work highlights the essential role of mechanical loading in driving mechanosignaling and postnatal growth trajectories in musculoskeletal tissues of the developing limb, with implications for overall musculoskeletal health in adulthood.

bioengineering↗

Limb Lengthening Induces Substantial Muscle Remodeling in Humans

To correct lower limb length discrepancies, orthopedic surgeons often perform limb lengthening procedures. These procedures involve directly lengthening a primary bone (e.g., femur), which also stretches the muscles and tendons spanning the elongation site. Limb lengthening procedures improve lower-limb length symmetry, often at the expense of chronic joint-level decrements. For example, knee joint range of motion and strength does not always return to pre-surgery values following femur lengthening. These joint-level decrements governed by altered muscle force-length characteristics, but it is unestablished how human muscles remodel during surgical limb lengthening. Here, we characterized bilateral human vastus lateralis fascicle force-length profiles following femur lengthening. At 2.2 {+/-} 1.7 years (Avg {+/-} SE) post-initial surgery, the lengthened limb's vastus lateralis fascicles were longer, effectively stiffer, and weaker than the contralateral limb. The lengthened limb's vastus lateralis fascicles were 38 mm longer (Avg) than that of the contralateral limb, even though the lengthened limb's femur was only 31 mm longer (Avg). The onset of vastus lateralis fascicle passive force production began at 22% shorter (Avg) operating lengths in lengthened versus contralateral limb muscles. Additionally, vastus lateralis peak active force production was 34% less (Avg) in the lengthened versus contralateral limbs, and in-series quadriceps tendon stiffness was not stiffer in lengthened limbs. These data suggest that active muscle tissues lengthen more than passive muscle tissues following limb lengthening, effectively creating stiffer muscles. Years after limb lengthening, patient muscles exhibit numerous differences in their force-length properties versus that of natural growth, likely contributing to impaired joint-function.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

In vivo characterization of Achilles subtendon function and morphology within the tendon cross section and along the free tendon

The Achilles tendon is composed of three distinct fascicle bundles, or "subtendons," each originating from the head of one of the three triceps surae muscles. In a healthy tendon, these subtendons slide relative to each other during muscle contractions. This subtendon sliding is reduced in older adults and younger adults who suffer an Achilles tendon injury. However, subtendon sliding is challenging to quantify in low-load scenarios that are critical for monitoring subtendon biomechanics in patients with mechanically compromised tendons, like following an Achilles tendon rupture and repair surgery. The purpose of this study was to develop a reliable method to characterize subtendon behavior in vivo using combined transverse plane ultrasound imaging and neuromuscular electrical stimulation of individual gastrocnemii. We used a Kanade-Lucas-Tomasi point tracking algorithm to quantify tendon displacement during isolated muscle stimulations. Next, we applied k-means clustering to characterize heterogeneous subtendon behavior within the tendon cross section. The tendon cross section displayed differential displacement patterns depending on the stimulated muscle (p<0.0001), and these displacements differed along the free tendon during lateral gastrocnemius stimulations (p=0.004). These results reflect possible differences in load-sharing between adjacent subtendons and differing muscle-tendon dynamics among the triceps surae muscles. Finally, this method confirmed bilaterally symmetric subtendon behavior and demonstrated high inter-session reliability (ICC>0.83). Overall, this study furthers our understanding of differential muscle-tendon dynamics of individual Achilles subtendons both within the tendon cross section and along the free tendon. Future work will apply this method to injured populations to develop biomarkers of altered subtendon function. NEW & NOTEWORTHYAchilles subtendon function and morphology are challenging to characterize in vivo. This study employed transverse plane ultrasound imaging and neuromuscular electrical stimulation to characterize behavior of individual subtendons both within the tendon cross section and along the free tendon. It is the first study to demonstrate functional behavior within the Achilles tendon using these combined tools in identifying subtendon dynamics. Additional findings of bilateral symmetry in healthy individuals present this tools potential to quantify altered subtendon function post-injury.

bioengineering↗

Markerless motion capture estimates of lower extremity kinematics and kinetics are comparable to marker-based across 8 movements

Motion analysis is essential for assessing in-vivo human biomechanics. Marker-based motion capture is the standard to analyze human motion, but the inherent inaccuracy and practical challenges limit its utility in large-scale and real-world applications. Markerless motion capture has shown promise to overcome these practical barriers. However, its fidelity in quantifying joint kinematics and kinetics has not been verified across multiple common human movements. In this study, we concurrently captured marker-based and markerless motion data on 10 healthy subjects performing 8 daily living and exercise movements. We calculated the correlation (Rxy) and root-mean-square difference (RMSD) between markerless and marker-based estimates of ankle dorsi-plantarflexion, knee flexion, and three-dimensional hip kinematics (angles) and kinetics (moments) during each movement. Estimates from markerless motion capture matched closely with marker-based in ankle and knee joint angles (Rxy [&ge;] 0.877, RMSD [&le;] 5.9{degrees}) and moments (Rxy [&ge;] 0.934, RMSD [&le;] 2.66 % height x weight). High outcome comparability means the practical benefits of markerless motion capture can simplify experiments and facilitate large-scale analyses. Hip angles and moments demonstrated more differences between the two systems (RMSD: 6.7{degrees} - 15.9{degrees} and up to 7.15 % height x weight), especially during rapid movements such as running. Markerless motion capture appears to improve the accuracy of hip-related measures, yet more research is needed for validation. We encourage the biomechanics community to continue verifying, validating, and establishing best practices for markerless motion capture, which holds exciting potential to advance collaborative biomechanical research and expand real-world assessments needed for clinical translation.

bioengineering↗

Plantar flexor deficits following Achilles tendon rupture: a novel small animal dynamometer and detailed instructions

Plantar flexor functional deficits measured using joint dynamometry are associated with poor outcomes in patients following Achilles tendon rupture. In this study, we developed a small animal dynamometer to quantify functional deficits in a rat Achilles tendon rupture model. Like our reported plantar flexor deficits in patients recovering from Achilles tendon ruptures, we found in our small animal model functional deficits across the ankle range of motion, resulting in an average 34% less positive work being done compared to the uninjured contralateral limb. These functional deficits are similar to 38% less plantar flexor work done by patients who were treated non-surgically in our prior research. Further, these deficits were greater in plantar flexion than dorsiflexion, which agree with clinical complaints of limited function during tasks like jumping and hiking. These findings highlight the impact of muscle-tendon loading during early tendon healing on long-term plantar flexor function and serve as compelling evidence that our Sprague Dawley rat model of an Achilles tendon rupture recapitulates the human disease. We provide thorough documentation for other groups to build their own dynamometers, which can be modified to meet unique experimental criteria. SIGNIFIGANCEPreclinical models are critical tools for translating knowledge discovery to clinical decision making. We developed a low-cost and flexible joint dynamometer that quantifies joint function in small animals. Here, we used a rat model to test the implications of Achilles tendon ruptures not surgically repaired on plantar flexor function. We found that Achilles tendon ruptures in a rodent model closely resemble the functional deficits our group has observed in patients.

bioengineering↗

Experimental recommendations for estimating lower extremity loading based on joint and activity

Researchers often estimate joint loading using musculoskeletal models to solve the inverse dynamics problem. This approach is powerful because it can be done non-invasively, however, it relies on assumptions and physical measurements that are prone to measurement error. The purpose of this study was to determine the impact of these errors - specifically, segment mass and shear ground reaction force - have on analyzing joint loads during activities of daily living. We preformed traditional marker-based motion capture analysis on 8 healthy adults while they completed a battery of exercises on 6 degree of freedom force plates. We then scaled the mass of each segment as well as the shear component of the ground reaction force in 5% increments between 0 and 200% and iteratively performed inverse dynamics calculations, resulting in 1,681 mass-shear combinations per activity. We compared the peak joint moments of the ankle, knee, and hip at each mass-shear combination to the 100% mass and 100% shear combination to determine the percent error. We found that the ankle was most resistant to changes in both mass and shear and the knee was resistant to changes in mass while the hip was sensitive to changes in both mass and shear. These results can help guide researchers who are pursuing lower-cost or more convenient data collection setups.

bioengineering↗

Moving outside the lab: markerless motion capture accurately quantifies sagittal plane kinematics during the vertical jump

Markerless motion capture using deep learning approaches have potential to revolutionize the field of biomechanics by allowing researchers to collect data outside of the laboratory environment, yet there remain questions regarding the accuracy and ease of use of these approaches. The purpose of this study was to apply a markerless motion capture approach to extract lower limb angles in the sagittal plane during the vertical jump and to evaluate agreement between the custom trained model and gold stand motion capture. We performed this study using a large open source data set (N=84) that included synchronized commercial video and gold standard motion capture. We split these data into a training set for model development (n=69) and test set to evaluate capture performance relative to gold standard motion capture using coefficient of multiple correlations (CMC) (n=15). We found very strong agreement between the custom trained markerless approach and marker-based motion capture within the test set across the entire movement (CMC>0.991, RMSE<3.22{degrees}), with at least strong CMC values across all trials for the hip (0.853 {+/-} 0.23), knee (0.963 {+/-} 0.471), and ankle (0.970 {+/-} 0.055). The strong agreement between markerless and marker-based motion capture provides evidence that markerless motion capture is a viable tool to extend data collection to outside of the laboratory. As biomechanical research struggles with representative sampling practices, markerless motion capture has potential to transform biomechanical research away from traditional laboratory settings into venues convenient to populations that are under sampled without sacrificing measurement fidelity.

bioengineering↗

Passive Novel Isodamping Dynamometer for Mobile Measurement of Plantar Flexor Function

Isokinetic dynamometers are the gold standard tools used to assess in vivo joint and muscle function in human subjects, however, the large size and high cost of these devices prevents their widespread use outside of biomechanics lab. In this study, we developed a mobile dynamometer to allow for field measurements of joint level function. To ensure subject safety, we designed a new "isodamping" dynamometer that acted as passive energy sink which constrains velocity by forcing incompressible oil through an orifice with an adjustable diameter. We validated the performance of this device by testing plantar flexor function in six healthy adults on both a commercial isokinetic dynamometer and this novel device at three velocities/damper settings and at three different effort levels. During maximal effort contraction, measurements of peak moment and velocity at peak moment of the novel device and the commercial device were strongly correlated along the predicted quadratic line (R2 > 0.708, p [&le;] 0.008). The setting of the damper prescribed the relationship between peak moment and velocity at peak moment across all subjects and effort levels (R2 > 0.91, p < 0.001). The novel device was significantly smaller (0.75 m2 footprint), lighter (30 kg), and lower cost (~$2,200 US) than commercial devices compared to commercially-available isokinetic dynamometers (5.95 m2 footprint, 450 kg, and ~$40,000 US respectively).

bioengineering↗

Instrumented immobilizing boot quantifies reduced Achilles tendon loading during gait

Achilles tendon ruptures are common injuries that lead to functional deficits in two-thirds of patients. Progressively loading the healing tendon has been associated with superior outcomes, but the loading profiles that patients experience throughout rehabilitation have not yet been established. In this study, we developed and calibrated an instrumented immobilizing boot paradigm that is aimed at longitudinally quantifying patient loading biomechanics to develop personalized rehabilitation protocols. We used a 3-part instrumented insole to quantify the ankle loads generated by the Achilles tendon and secured a load cell in-line with the posterior strut of the immobilizing boot to quantify boot loading. We then collected gait data from five healthy young adults to demonstrate the validity of this instrumented immobilizing boot paradigm to assess Achilles tendon loading during ambulation. We developed a simple calibration procedure to improve the measurement fidelity of the instrumented insole needed to quantify Achilles tendon loading while ambulating with an immobilizing boot. By assessing Achilles tendon loading with the ankle constrained to 0 degrees and 30 degrees plantar flexion, we confirmed that walking with the foot supported in plantar flexion decreased Achilles tendon loading by 60% (P < 0.001). This instrumented immobilizing boot paradigm leverages commercially available sensors and logs data using a small microcontroller secured to the boot and a handheld device, making our paradigm capable of continuously monitoring biomechanical loading outside of the lab or clinic.

bioengineering↗

Novel instrumented insole algorithm accurately approximates plantar flexor loading

Plantar flexor loading is critical for ambulatory function but there are few wearable solutions to monitor loading. The purpose of this study was to develop and validate a method to quantify plantar flexor loading using a commercially-available instrumented insole. Seven healthy young adults completed a battery of functional activities to characterize a range of plantar flexor loading which included single leg heel raise, step down, and drop jump as well as walking and running at comfortable speeds. Lower extremity trajectories were captured using motion capture and ground reaction forces were recorded with embedded force plates as well as the instrumented insole. Measurements of plantar flexor loading quantified by the instrumented insole were compared to gold standard inverse dynamics. We found that the insole loading calculation of plantar flexor moment was accurate to within 4.2% on average compared to inverse dynamics across all activities. Additionally, the calculated wave forms were strongly correlated with inverse dynamics (Rxy > 0.928). Our findings demonstrate the utility and fidelity of a new method for measuring plantar flexor loading using a commercially available instrumented insole. By leveraging this new methodology, it is now feasible to prospectively track and eventually prescribe plantar flexor loading outside of the clinic to improve patient outcomes.

bioengineering↗

Ultrasound Echogenicity is Associated with Achilles Tendon Fatigue Damage in a Cadaveric Loading Model

Achilles tendon disorders are among the most difficult sports-related injuries to predict with current diagnostic tools. The purpose of this study was to identify a clinically useful marker for early tendon damage. We hypothesized that alterations in mean echogenicity are linked with changes in vitro tendon mechanics. To test our hypothesis, we harvested Achilles tendons from 10 fresh-frozen cadaveric feet and cyclically fatigued them using a universal test frame while we continuously acquired ultrasound images. Throughout this fatigue protocol, we applied 2 stress tests every 500 loading cycles to quantify changes in ultrasound imaging echogenicity. We continued this fatigue protocol until each tendon either failed completely or survived 150,000 cycles. Tendons that failed during the fatigue loading (6/10) underwent greater changes in mean echogenicity compared to tendons that did not fail (P = 0.031). These tendons that failed during fatigue loading demonstrated greater changes in mean echogenicity that surpassed 1.0%; whereas survivor tendons exhibited less than 0.5% changes in mean echogenicity. We found that changes in mean echogenicity measured with ultrasound increased proportionally with increased tendon damage. The magnitude of these changes was relatively small (<1.5% change in mean echogenicity) but may be an effective predictor of tendon failure. Mean echogenicity is a promising marker for quantifying fatigue damage in cadaveric Achilles tendons during a stress test. Although these changes cannot be detected with the naked eye, computer-based predictive models may effectively assess risk of tendon damage in physically active adults. Level of evidenceControlled laboratory experiment

bioengineering↗

Designing and validating a staircase to leverage floor mounted force plates

Navigating stairs is a challenging task for many patient populations. Unfortunately, assessing lower extremity kinetics is not practical in many laboratories due in part to methodologic constraints. In this study, we designed, fabricated, and calibrated a staircase that accurately measured ground reaction forces applied to the second and fourth step. This implementation met several design criteria that included low-cost, ability to quickly move the staircase in and out of motion capture spaces, stable and safe staircase, and easily modifiable to meet the constraints of different lab layouts. We built the staircase as an outer and inner staircase assembly constructed using a modular aluminum framing system. Once positioned on our force plates that were embedded in the lab floor, we used an instrumented pole to apply known loads to a series of surface locations on the force plates and steps that were resting on top of the force plates. This calibration procedure reduced the center of pressure errors by approximately 50% for the embedded force plates and lower step (step 2) and 3-fold for the higher step (step 4). Next, we demonstrated that these steps can be integrated into a clinical gait analysis workflow. A single healthy-young adult navigated the stairs, the ground reaction forces were transformed into stair reaction forces, and these external loads were used to solve the inverse dynamics problem. This staircase provides other researchers with a new tool to assess stair navigation biomechanics. In this study, we provided the bill of materials, mechanical drawings, and calibration code necessary to modify and implement this staircase paradigm into other lab layouts.

bioengineering↗

Gastrocnemius muscle remodeling explains functional deficits three months following Achilles tendon rupture

Plantarflexor functional deficits are associated with poor outcomes in patients following Achilles tendon rupture. In this longitudinal study, we analyzed the fascicle length and pennation angle of the medial gastrocnemius muscle and the length of the Achilles tendon using ultrasound imaging. To determine the relationship between muscle remodeling and functional deficits measured at 3 months after injury, we correlated the reduction in fascicle length and increase in pennation angle with peak torque measured during isometric plantarflexor contractions and peak power measured during isokinetic plantarflexor contractions. We found that the medial gastrocnemius underwent an immediate change in structure, characterized by decreased length and increased pennation of the muscle fascicles. This decrease in fascicle length was coupled with an increase in tendon length. These changes in muscle-tendon structure persisted throughout the first three months following rupture. Deficits in peak plantarflexor power were moderately correlated with decreased fascicle length at 120 degrees per second (R2 = 0.424, P = 0.057) and strongly correlated with decreased fascicle length at 210 degrees per second (R2 = 0.737, P = 0.003). However, increases in pennation angle did not explain functional deficits. These findings suggest that muscle-tendon structure is detrimentally affected following Achilles tendon rupture. Plantarflexor power deficits are positively correlated with the magnitude of reductions in fascicle length. Preserving muscle structure following Achilles tendon rupture should be a clinical priority to maintain patient function.

physiology↗

Plantarflexor Torque and Work is Positively Correlated with Medial Gastrocnemius Fascicle Length in Healthy Young Adults

Ankle kinetics are critical for ambulatory function in elite athletes, the elderly, and many patient populations. Despite the robust findings linking plantarflexor muscle structure to gross function with these populations, the link between plantarflexor fascicle length and ankle kinetics has not been established in the literature. In this study, we determined the relationship between muscle structure and peak torque and total work produced by the plantarflexors during maximal effort contractions. We measured resting fascicle length and pennation angle of the medial gastrocnemius using ultrasound in healthy adult subjects (n=12). Subjects performed contractions on a dynamometer during isokinetic and isometric conditions. Longer fascicles were positively correlated with higher peak torque and total work (R2 > 0.41, p < 0.013) across all isokinetic velocities. Higher pennation angles were negatively correlated with peak torque and total work (R2 > 0.296, p < 0.067). None of these correlations were significant in isometric conditions. This provides experimental evidence demonstrating the link between plantarflexor muscle structure and ankle kinetics in healthy young adults which has hitherto not been experimentally demonstrated in existing literature.

bioengineering↗

Gastrocnemius fascicles are shorter and more pennate immediately following acute Achilles tendon rupture

The purpose of this study was to characterize the short-term effects of Achilles tendon ruptures on medial gastrocnemius. We hypothesized that the fascicles of the medial gastrocnemius muscle of the injured Achilles tendon would be shorter and more pennate immediately following the injury and would persist throughout 4 weeks post-injury. B-mode longitudinal ultrasound images of the medial gastrocnemius were acquired in 10 adults who suffered acute Achilles tendon ruptures and were treated non-operatively. Ultrasound images were acquired during the initial clinical visit following injury as well as two and four weeks following this initial clinical visit. Resting muscle structure was characterized by measuring fascicle length, pennation angle, muscle thickness, and muscle echo intensity in both the injured and contralateral (control) limbs. Fascicle length was 15% shorter (P < 0.001) and pennation angle was 21% greater (P < 0.001) in the injured muscle compared to the uninjured (control) muscle at the presentation of injury (week 0). These differences in fascicle length and pennation angle persisted throughout the 4 weeks after the injury (P < 0.008). Muscle thickness changes were not detected at any of the post-injury visits (difference < 4%, P > 0.04). Echo intensity of the injured limb was 8% lower at the presentation of the injury and 11% lower (P = 0.008) than the contralateral muscle at 2 weeks following injury (P < 0.001) but returned to within 1% by 4 weeks (P = 0.393). Our results suggest that Achilles tendon ruptures elicit rapid changes in the configuration and quality of the medial gastrocnemius, which may explain long-term functional deficits.

bioengineering↗

Plantarflexor fiber length and tendon slack length are the strongest determinates of simulated single-leg heel raise function

AbstractAchilles tendon ruptures lead to reduced ankle function and often limits recreational activity. Single-leg heel raises are often used clinically to characterize patient function. However, it is unclear how the structure of the Achilles tendon and plantarflexor muscles affects single-leg heel raise function. Therefore, the purpose of this study was to develop a musculoskeletal model in order to simulate the effects of muscle-tendon unit (MTU) parameters on peak plantarflexion during this clinically-relevant task. The ankle joint was plantarflexed by two MTUs that represented the soleus and gastrocnemius muscles. The optimal fiber length, maximal muscle force, muscle pennation, tendon stiffness, and resting ankle angle - a surrogate measure of tendon slack length - were iteratively adjusted to test the combined effects of each of these MTU parameters. Single-leg heel raises were simulated by maximally exciting the two plantarflexor MTUs for each model configuration (N = 161,051 simulations). Optimal muscle fiber and tendon slack lengths had the greatest effect on peak plantarflexion during simulated single-leg heel raises. Simulations that were unable to produce at least 30 degrees of plantarflexion had muscle fibers that were shorter than healthy muscle and longer tendon slack lengths. These findings highlight the importance of preserving muscle fascicle and tendon length following Achilles tendon injuries.\n\nFunding no funding has been provided for this research\n\nAcknowledgements the Authors have no acknowledgements\n\nConflict of interest the Authors have no conflicts of interest that are relevant to this work

bioengineering↗

Tendon Structure Quantified using Ultrasound Imaging Differs Based on Location and Training Type

Achilles tendinopathy is ten-times more common amongst running athletes compared to age-matched peers. Load induced tendon remodeling and its progression in an at-risk population of developing symptomatic tendinopathy is not well understood. The purpose of this study was to prospectively characterize Achilles and patellar tendon structure in competitive collegiate distance runners over different competitive seasons using quantitative ultrasound imaging. Twenty-two collegiate cross country runners and eleven controls were examined for this study. Longitudinal and cross-sectional ultrasound images of bilateral Achilles and patellar tendons were obtained at the one week prior to start of formal collegiate cross country practices, one week after the conclusion of cross country season, and one week prior to outdoor track and field championships. Collagen organization, mean echogenicity, tendon thickness, and neovascularity were determined using well established image processing techniques. We found that Achilles and patellar tendons respond differently to high-volume running and transitions from one sport season to another, suggesting that tendon structure is sensitive to differences in tendon loading biomechanics. Our findings indicate that Achilles tendon structure in trained runners differ structurally to control tendons but is stable throughout training while patellar tendon structure changes in response to the transition in training volume between cross country and track seasons. These findings expand upon prior reports that some degree of tendon remodeling may act as a protective adaptation for sport specific loading.\n\nNews and NoteworthyIn this study we prospectively examined the Achilles and patellar tendon structure of distance runners to determine if continued training through multiple seasons elicits tendon remodeling or pathology. We found that Achilles and patellar tendons respond uniquely to the changing loads required during each season. Achilles tendon collagen alignment is mostly stable throughout the competitive cycle, but the patellar tendon undergoes structural changes following the transition from cross-country to track season.

bioengineering↗