Search bioRxiv⌕ Search

Biology subjects

Balchandani, P.

Publications and source records attributed to Balchandani, P..

6 recordsLinked to original sources

Frequency Shift Imaging Using an Adiabatic SLR Self-Refocused Pulse for Positive-Contrast SPION Imaging at 7T

Abstract: Purpose: Superparamagnetic iron oxide nanoparticles (SPION) are widely used as MRI contrast agents for cell tracking and molecular imaging. However, their detection using conventional T2/T2* weighted and susceptibility-weighted MRI relies on negative contrast (signal voids), which lacks specificity because similar hypointense signals can arise from other sources of magnetic susceptibility. This study introduces Frequency Shift Imaging (FSI), a positive-contrast technique based on an adiabatic Shinnar-Le Roux (SLR) self-refocused pulse that addresses the limited specificity of conventional SPION imaging. Methods: An adiabatic self-refocused RF pulse was designed using the SLR algorithm for frequency-selective positive-contrast imaging. The optimized pulse had a spectral bandwidth of 370 Hz, a peak RF amplitude of 14 T, and a duration of 15 ms. FSI data were acquired on a 7T MRI scanner. Phantom experiments used agarose-embedded 30 nm cell-labeled SPION at 0%, 25%, 75%, and 100% concentrations (pure). In vivo validation was performed following intramuscular SPION injection into the hind limb of a mouse. FSI images were compared with conventional acquisitions. Results: Quantitative phantom analysis showed normalized FSI signal intensities of 25.02% and 75.16% for samples containing 25% and 75% labeled cells, respectively, demonstrating an approximately proportional relationship between FSI signal and labeled-cell concentration. In vivo, FSI generated localized hyperintense positive contrast at the SPIO injection site, providing improved conspicuity and localization compared with the corresponding negative-contrast signal void. Discussion and Conclusion: FSI enables robust, B1-insensitive, positive-contrast SPION imaging at 7T with reduced echo time and SAR compared to paired adiabatic approaches, supporting its potential for quantitative cell tracking and molecular imaging applications.

bioengineering↗

Receive-Only Coupled Wireless Radiofrequency Probe for Endocavity MR Imaging Using a pTx System

PurposeTo enhance the SNR in MRI within a localized region of interest using a novel interventional wireless RF resonator probe combined with a dual-drive pTx system. MethodsA dual-drive body birdcage coil was operated in a linearly-polarized mode to decouple a passive RF resonator probe from the transmit field while maintaining the resonator in a receive-only coupled mode. The resonator was fabricated using standard microfabrication techniques and tuned to the Larmor frequency of a 3T MRI system. The 10-g specific absorption rate (SAR) distribution was simulated to identify potential hot spots around the resonator prior to heating experiments. To evaluate the interaction between the resonator probe and the linearly-polarized transmit field, SNR and flip-angle distributions were measured in a phantom. In vivo imaging studies were subsequently performed using the resonator probe in conjunction with the linearly-polarized dual-drive birdcage coil. ResultsTemperature measurements demonstrated a normalized temperature increase of less than 0.10{degrees}C, corresponding to a SAR value below 1.21 W/kg. Experimental flip-angle mapping confirmed effective magnetic decoupling of the resonator probe using linearly-polarized dual-drive transmission. An SNR enhancement factor of 1.6 was achieved within the region of interest in phantom experiments. In vivo imaging demonstrated a 2.0 {+/-} 0.2-fold SNR enhancement in the vicinity of the resonator probe. ConclusionA novel interventional approach for localized SNR enhancement in MRI was demonstrated using a wireless RF resonator probe and a dual-drive pTx system. The proposed technique enables local signal enhancement while minimizing transmit-field interactions, thereby facilitating safe interventional MRI and potentially improving image quality and diagnostic performance.

bioengineering↗

Optimized Quantitative Susceptibility Mapping at 7T MRI for Assessing Iron Deposition in Alzheimers Disease

INTRODUCTIONElevated brain iron levels are common in Alzheimers disease (AD). Quantitative Susceptibility Mapping (QSM) is an advanced MRI technique for assessing iron accumulation. The optimized QSM at 7 Tesla (7T) MRI may further improve the sensitivity to detect subtle susceptibility changes in AD. METHODSWe optimized a QSM processing pipeline for 7T MRI by systematically comparing multiple reconstruction algorithms. Evaluation criteria included image quality, artifact suppression, and anatomical clarity. The finalized pipeline was applied to individuals with AD and healthy controls (HCs). RESULTSThe results revealed significantly elevated magnetic susceptibility values in the globus pallidus and dentate nucleus of the AD group compared to HCs. These findings were confirmed through both visual inspection and quantitative analysis of high-resolution QSM maps. DISCUSSIONOur results highlight the importance of optimizing QSM pipelines at 7T for accurate susceptibility quantification. We identified an optimal pipeline suitable for future applications in patients with AD and other neurological conditions.

neuroscience↗

Differential patterns of automatic segmentation of 3T and 7T MRI: Implications in neuropsychiatric disease

Automatic segmentation was performed on T1-MPRAGE structural MRI data acquired at 3T and 7T from 37 and 69 distinct healthy controls, respectively. Additionally, segmentation was performed on imaging acquired from 215 major depressive disorder (MDD) patients at 3T and 40 MDD patients at 7T. Of 259 segmentation-derived imaging features evaluated, 120 showed significant 3T vs. 7T differences among controls, and 153 among patients. 7T imaging metrics showed consistently lower cortical thickness and cortical gray/white matter ratios. Subcortical and cortical volumes measured at 7T were more mixed, with 7T images showing greater frontal lobe volume, but lower cortical volumes elsewhere.

bioengineering↗

Perivascular Space Semi-Automatic Segmentation (PVSSAS): A Tool for Segmenting, Viewing and Editing Perivascular Spaces

ObjectiveIn this study, we validate and describe a user-friendly tool for PVS tracing that uses a Frangi-based detection algorithm; which will be made freely available to aid in future clinical and research applications. All PVS detected by the semi-automated method had a match with the manual dataset and 94% of the manual PVS had a match within the semi-automated dataset. MethodsWe deployed a Frangi-based filter using a pre-existing Matlab toolbox. The PVSSAS tool pre-processes the images and is optimized for maximum effectiveness in this application. A user-friendly GUI was developed to aid the speed and ease in marking large numbers of PVS across the entire brain at once. ResultsUsing a tolerance of 0.7 cm, 83% of all PVSs detected by the semi-automated method had a match with the manual dataset and 94% of the manual PVS had a match within the semi-automated dataset. As shown in figure 3, there was generally excellent agreement between the manual and semi-automated markings in any given slice. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=80 SRC="FIGDIR/small/385336v1_fig3.gif" ALT="Figure 3"> View larger version (19K): org.highwire.dtl.DTLVardef@35f651org.highwire.dtl.DTLVardef@be6b08org.highwire.dtl.DTLVardef@164ec0aorg.highwire.dtl.DTLVardef@c48643_HPS_FORMAT_FIGEXP M_FIG O_FLOATNOFigure 3&4C_FLOATNO Rendered 3-D view of total PVS found across all slices for one patient. C_FIG SignificanceThe primary benefit of PVSSAS will be time saved marking PVS. Clinical MRI use is likely to become more widespread in the diagnosis, treatment, and study of MS and other degenerative neurological conditions in the coming years. Tools like the one presented here will be invaluable in ensuring that the tracing and quantitative analysis of these PVS does not act as a bottle neck to treatment and further research.

neuroscience↗

Ultra-high field MRI reveals mood-related circuit disturbances in depression: A systematic comparison between 3-Tesla and 7-Tesla

Ultra-high field 7-Tesla (7T) MRI has the potential to advance our understanding of neuropsychiatric disorders, including major depressive disorder (MDD). To date, few studies have quantified the advantage of resting state functional MRI (fMRI) at 7T compared to 3-Tesla (3T). We conducted a series of experiments that demonstrate the improvement in temporal signal-to-noise ratio (TSNR) of a multi-echo fMRI protocol with ultra-high field 7T, compared to 3T MRI in healthy controls (HC). We also directly tested the enhancement in ultra-high field 7T fMRI signal power by examining the ventral tegmental area (VTA), a small midbrain structure that is critical to the expected neuropathology of MDD but difficult to discern with standard 3T MRI. We demonstrate 200-300% improvement in TSNR and resting state functional connectivity coefficients provided by ultra-high field 7T fMRI compared to 3T, indicating enhanced power for detection of functional neural architecture. A multi-echo based acquisition protocol and signal denoising pipeline afforded greater gain in signal power at ultra-high field compared to classic acquisition and denoising pipelines. Furthermore, ultra-high field fMRI revealed mood-related neuro-circuit disturbances in patients with MDD compared to HC, which were not detectable with 3T fMRI. Ultra-high field 7T fMRI may provide an effective tool for studying functional neural architecture relevant to MDD and other neuropsychiatric disorders.

neuroscience↗