Search bioRxiv⌕ Search

Biology subjects

Augustin, C. M.

Publications and source records attributed to Augustin, C. M..

5 recordsLinked to original sources

Fibrosis burden and spatial pattern affect left atrial appendage stasis in multi-beat multi-physics simulations

Purpose: Atrial fibrosis is associated with thromboembolic risk in atrial fibrillation, but how fibrosis-related contractile impairment alters blood transport in the left atrium (LA) and left atrial appendage (LAA) remains unclear. Prior multi-physics simulations coupled electromechanical (EM) and computational fluid dynamics (CFD) models to show that fibrosis impairs LA function and flow, but were limited to booster-only contraction and could not separate the effects of fibrosis burden from its spatial distribution. Here we examined how fibrosis burden and spatial pattern independently relate to long-term LA and LAA hemodynamics in full-cycle, multi-beat simulations on a common LA anatomy. Methods: Three fibrosis patterns derived from late gadolinium enhancement MRI were considered: one from the patient providing the common anatomy and two from additional patients, with the latter mapped onto the common anatomy via universal atrial coordinates. All three patterns were applied globally at matched burdens of 15.6% and 31.2%, yielding six global-fibrosis cases and a non-fibrotic reference. Two patterns were also confined to the LAA at three local burdens (10%, 25%, and 50%), yielding six LAA-fibrosis cases. A 3D EM model for the LA anatomy was coupled to a 0D circulatory model, so that the simulations resolved the reservoir, conduit, and booster phases. Full-cycle EM-derived wall motion drove subsequent multi-beat CFD simulations. Region-specific emptying fraction (EF), non-dimensional kinetic energy (KE), and the 90th percentile of blood residence time (TR) were evaluated for the LA and LAA. Results: Left ventricular stroke volume remained nearly constant across cases, while increasing global fibrosis burden progressively reduced LA and LAA EF (LA: 36% to 30-31%; LAA: 44% to 28-38%) and monotonically increased LA TR across all patterns. Non-dimensional LA KE showed an approximately quadratic association with LA EF across patterns, whereas LAA KE was more scattered but still increased with LAA EF. In contrast, the relationship between the 90th percentile of LAA TR and LAA EF showed pattern-specific, non-monotonic trends. Conclusions: Fibrosis burden and spatial distribution jointly shape LA and LAA hemodynamics, but through different mechanisms. LAA EF is a robust functional descriptor of chamber-averaged kinetic energy regardless of fibrosis pattern, whereas LAA blood stasis depends additionally on the spatial distribution of fibrosis beyond what bulk emptying fraction predicts. These findings support incorporating imaging-derived fibrosis pattern, and not only burden, alongside functional metrics when assessing thrombogenic risk in the LAA.

bioengineering↗

A Cohort-Based Global Sensitivity Benchmark of MRI-Derived Whole-Heart Electromechanical Models in Healthy Hearts

Patient-specific four-chamber electromechanical models provide a physics-constrained framework for investigating whole-heart cardiac physiology and disease mechanisms. Identifying which model parameters impact whole-heart function is important for understanding cellular-, tissue-, and organ-scale determinants of cardiac performance and for calibrating patient-specific models. However, previous global sensitivity analyses of cardiac electromechanical models have typically been performed on a single heart, and systematic evaluation of how parameter influence compares across anatomically different subjects remains limited. We created four-chamber electromechanical models using cardiac MRI from five healthy subjects (n = 5). The models simulated atrial and ventricular cellular electrophysiology, calcium dynamics, and active contraction, with heterogeneous fibre orientation, transversely isotropic tissue mechanics, pericardial constraint, and a closed-loop cardiovascular system providing physiological boundary conditions. In total, 46 parameters described the integrated model. Using Gaussian process emulators, we performed multi-scale global sensitivity analysis to evaluate the relative contribution of model parameters to left and right atrial and ventricular function. Across all anatomies, the most influential parameters were systemic and pulmonary resistances, ventricular end-diastolic pressures, and the venous reference pressure, highlighting the dominant role of haemodynamic loading conditions in governing pressure- and volume-based outputs. A chamber-level analysis of atrioventricular coupling revealed a phase-dependent pattern. Atrial pressures were predominantly governed by global haemodynamic parameters (> 90% of total sensitivity), atrial filling volumes showed substantial ventricular influence ({approx}40-55% across anatomies), and atrial end-systolic volumes were primarily determined by intrinsic atrial parameters ({approx}60-65%). These patterns were consistent across subjects despite differences in anatomy. We show that, in healthy male subjects, inter-individual anatomical variation does not substantially change the ranking of dominant parameters. This work provides a repeatable modelling and sensitivity analysis framework and establishes a benchmark reference for whole-heart electromechanical modelling in healthy hearts. Author summaryComputational models of the heart can simulate cardiac physiology in unprecedented detail, but these models contain many parameters whose influence on predicted function is not fully understood. We built patient-specific four-chamber heart models from MRI scans of five healthy subjects and used statistical methods to systematically test how 46 model parameters affect simulated cardiac performance. Across all five subjects, we found that the haemodynamic loading parameters, including systemic and pulmonary vascular resistance, ventricular filling pressures, and the venous reference pressure, consistently had the greatest influence on the model outputs, regardless of differences in individual heart anatomy. This finding suggests that in healthy resting conditions, the boundary conditions of the cardiovascular system, rather than individual differences in heart geometry or electrical properties, are the primary drivers of whole-heart function. We also found a structured coupling pattern between the upper and lower heart chambers, where global haemodynamic parameters dominate atrial pressure regulation, ventricular mechanics shape atrial filling, and intrinsic atrial properties control atrial emptying. This work provides a benchmark dataset of five anatomically detailed heart models and a sensitivity analysis framework to guide calibration of future cardiac digital twin models.

systems biology↗

Effect of Wall Motion Sampling on CFD-Derived Left Atrial Flow Metrics

The temporal resolution of medical imaging sequences used to drive patient-specific computational fluid dynamics (CFD) simulations remains limited, typically providing 10-20 frames per cardiac cycle. Therefore, temporal interpolation to reconstruct left atrial (LA) wall motion and boundary conditions is required, but its impact on hemodynamic predictions has not been systematically characterized. To investigate this, we constructed high-temporal-resolution reference wall-motion data using electromechanical (EM) simulations on five patient-specific atrial geometries with a history of atrial fibrillation. We then generated temporally downsampled datasets to emulate clinical frame rates (5, 10, 20, and 40 frames per cycle) and performed CFD simulations to isolate the effects of temporal undersampling on hemodynamic metrics. The focus was placed on kinetic energy, KE, and residence time, TR, particularly in the left atrial appendage (LAA), where thrombosis is most likely to occur. We employed an immersed boundary method to prescribe the wall motion and computed blood TR through a passive scalar transport equation. Results indicate that while global LA hemodynamic indices were marginally affected by the frame rate (errors < 9%), LAA metrics were more sensitive with errors up to 31% compared to reference values. The results based on 20 and 40 frames per cycle yielded favorable agreement with reference results, while 5-and 10-frame reconstructions showed larger, though not systematically biased, deviations from the reference. Importantly, patient ranking by blood-stasis indices was largely preserved. The analysis suggests that patientspecific LA reconstructions derived from dynamic CT imaging provide a reliable basis for estimating LAA blood-stasis indices. Higher frame rates ([&ge;] 20 per cycle) offer improved quantitative accuracy, while lower temporal resolutions may remain informative for patient stratification purposes, where relative ranking is more relevant than absolute accuracy.

bioengineering↗

Systematic computational assessment of atrial function impairment due to fibrotic remodeling in electromechanical properties

Cardiac fibrosis is a pathological condition associated with many cardiovascular diseases. Atrial fibrosis leads to reduced atrial function, resulting in diminished blood flow and an increased risk of stroke. This reduced function arises from altered myocardial electrophysiological and mechanical properties. Identifying the relative importance of these fibrosis-associated properties can reveal the most significant determinants of left atrial function impairment. In this study, we used a computational framework to investigate the relative importance of various fibrosis-associated properties. Our model, a 3D electromechanical framework coupled with a 0D circulatory model, incorporated patient-specific geometries and fibrosis distributions from clinical imaging data. Nine parameters related to fibrotic remodeling (conduction velocity, ion channel expression levels, cell- and tissue-scale contractility, and stiffness) were analyzed using two sensitivity analysis schemes: a one-factor-at-a-time setup, allowing for the analysis of isolated effects, and a fractional factorial design, enabling the examination of combined effects. As output, we tracked various metrics derived from model-predicted pressure-volume loops. Impairment of L-type calcium current (ICaL) was most detrimental (up to 64% reduction in A-loop area). Conversely, reduced inward rectifier current (IK1) led to improved atrial function (up to 27% increase in A-loop area). Fractional factorial design analysis revealed that combination with other parameter changes blunted the impact of reduced ICaL but amplified the impact of reduced IK1. Further analysis of spatiotemporal distributions linked these effects to changes in intracellular calcium handling. Future research focusing on IK1 and ICaL could be highly significant for clinical and scientific advances. Modeling work can potentially help evaluate left atrial function among larger patient cohorts, focusing on strain analysis. Our work could also be extended to spatiotemporal simulations of blood flow and thrombosis, shedding light onto the mechanisms underlying atriogenic stroke. Author summaryCardiac fibrosis is a process where healthy heart muscle is replaced with non-conductive, non-contractile tissue. This change disrupts how the heart beats and contracts. In the left atrium, fibrosis is strongly linked to atrial fibrillation and a higher risk of stroke, the latter due to impaired pumping and altered blood flow. In this study, we used a detailed computer model of the heart, based on real patient-specific left atrial shapes and fibrosis patterns, to understand how different fibrosis-related changes affect atrial function. We tested nine features of the hearts electrical and mechanical behavior that are known to change during fibrosis, aiming to identify which ones have the most impact on the atrial function. We found that reducing the L-type calcium current -- an important signal for muscle contraction -- caused the greatest decrease in atrial performance. Surprisingly, reducing the inward rectifier potassium current actually improved it. These effects were tied to changes in calcium handling inside heart cells. Our findings highlight promising directions for future heart disease research and treatment.

systems biology↗

Neural network emulation of the human ventricular cardiomyocyte action potential: a tool for more efficient computation in pharmacological studies

AbstractComputer models of the human ventricular cardiomyocyte action potential (AP) have reached a level of detail and maturity that has led to an increasing number of applications in the pharmaceutical sector. However, interfacing the models with experimental data can become a significant computational burden. To mitigate the computational burden, the present study introduces a neural network (NN) that emulates the AP for given maximum conductances of selected ion channels, pumps, and exchangers. Its applicability in pharmacological studies was tested on synthetic and experimental data. The NN emulator potentially enables massive speed-ups compared to regular simulations and the forward problem (find drugged AP for pharmacological parameters defined as scaling factors of control maximum conductances) on synthetic data could be solved with average root-mean-square errors (RMSE) of 0.47 mV in normal APs and of 14.5 mV in abnormal APs exhibiting early afterdepolarizations (72.5% of the emulated APs were alining with the abnormality, and the substantial majority of the remaining APs demonstrated pronounced proximity). This demonstrates not only very fast and mostly very accurate AP emulations but also the capability of accounting for discontinuities, a major advantage over existing emulation strategies. Furthermore, the inverse problem (find pharmacological parameters for control and drugged APs through optimization) on synthetic data could be solved with high accuracy shown by a maximum RMSE of 0.21 in the estimated pharmacological parameters. However, notable mismatches were observed between pharmacological parameters estimated from experimental data and distributions obtained from the Comprehensive in vitro Proarrhythmia Assay initiative. This reveals larger inaccuracies which can be attributed particularly to the fact that small tissue preparations were studied while the emulator was trained on single cardiomyocyte data. Overall, our study highlights the potential of NN emulators as powerful tool for an increased efficiency in future quantitative systems pharmacology studies.

cell biology↗