Search bioRxiv⌕ Search

Biology subjects

Andreasson, J.

Publications and source records attributed to Andreasson, J..

3 recordsLinked to original sources

Demonstration of electron diffraction from membrane protein crystals grown in a lipidic mesophase after lamella preparation by focused ion beam milling at cryogenic temperatures

Electron crystallography of sub-micron sized 3D protein crystals has emerged recently as a valuable field of structural biology. In meso crystallization methods, utilizing lipidic mesophases, particularly lipidic cubic phases (LCPs), can produce high-quality 3D crystals of membrane proteins (MPs). A major step towards realising 3D electron crystallography of MP crystals, grown in meso, is to demonstrate electron diffraction from such crystals. The first task is to remove the viscous and sticky lipidic matrix, surrounding the crystals without damaging the crystals. Additionally, the crystals have to be thin enough to let electrons traverse them without significant multiple scattering. In the present work, we experimentally verified the concept that focused ion beam milling at cryogenic temperatures (cryo-FIB) can be used to remove excess host lipidic mesophase matrix, and then thin the crystals to a thickness suitable for electron diffraction. In this study, bacteriorhodopsin (BR) crystals grown in a lipidic mesophase of monoolein were used as a model system. LCP from a part of a 50-μm thick crystal, which was flash-frozen in liquid nitrogen, was milled away with a gallium FIB under cryogenic conditions, and a part of the crystal itself was thinned into a ∼210-nm thick lamella with the ion beam. The frozen sample was then transferred into an electron cryo-microscope (cryo-EM), and a nanovolume of ∼1400×1400×210 nm3 of the BR lamella was exposed to 200-kV electrons at a fluence of ∼0.06 e−/Å2. The resulting electron diffraction peaks were detected beyond 2.7-Å resolution (with mean signal-to-noise ratio <I/σ(I)> of >7) by a CMOS-based Ceta 16M camera. The results demonstrate, that cryo-FIB milling produces high quality lamellae from crystals grown in lipidic mesophases, and pave the way for 3D electron crystallography on crystals grown or embedded in highly viscous media.Synopsis Electron diffraction experiments on crystals of membrane proteins grown in lipidic mesophases have not been possible due to a thick layer of viscous crystallisation medium around the crystals. Here we show that focused ion beam milling at cryogenic temperatures (cryo-FIB milling) can remove the viscous layer, and demonstrate high-quality electron diffraction on a FIB-milled lamella of a bacteriorhodopsin 3D crystal.Competing Interest StatementThe authors have declared no competing interest.View Full Text

biophysics↗

Crowdsourced RNA design discovers diverse, reversible, efficient, self-contained molecular sensors

Internet-based scientific communities promise a means to apply distributed, diverse human intelligence towards previously intractable scientific problems. However, current implementations have not allowed communities to propose experiments to test all emerging hypotheses at scale or to modify hypotheses in response to experiments. We report high-throughput methods for molecular characterization of nucleic acids that enable the large-scale videogame-based crowdsourcing of functional RNA sensor design, followed by high-throughput functional characterization. Iterative design testing of thousands of crowdsourced RNA sensor designs produced near-thermodynamically optimal and reversible RNA switches that act as self-contained molecular sensors and couple five distinct small molecule inputs to three distinct protein binding and fluorogenic outputs--results that surpass computational and expert-based design. This work represents a new paradigm for widely distributed experimental bioscience. One Sentence SummaryOnline community discovers standalone RNA sensors.

synthetic biology↗

Electrospray sample injection for single-particle imaging with X-ray lasers

The possibility of imaging single proteins constitutes an exciting challenge for X-ray lasers. Despite encouraging results on large particles, imaging small particles has proven to be difficult for two reasons: not quite high enough pulse intensity from currently available X-ray lasers and, as we demonstrate here, contamination of the aerosolised molecules by non-volatile contaminants in the solution. The amount of contamination on the sample depends on the initial droplet-size during aerosolisation. Here we show that with our electrospray injector we can decrease the size of aerosol droplets and demonstrate virtually contaminant-free sample delivery of organelles, small virions, and proteins. The results presented here, together with the increased performance of next generation X-ray lasers, constitute an important stepping stone towards the ultimate goal of protein structure determination from imaging at room temperature and high temporal resolution.

biophysics↗