Search bioRxiv⌕ Search

Biology subjects

Anderson, A. W.

Publications and source records attributed to Anderson, A. W..

At least 19 recordsLinked to original sources

White-Matter BOLD Mediates Time-Varying Cortico-Cortical Functional Connectivity

Functional connectivity (FC) measurements in the brain using BOLD fMRI have largely focused on correlations between gray-matter (GM) BOLD signals, ignoring the possible relevance of white-matter (WM) in delineating neural networks. We first employed a tract-informed mediation framework to test whether WM pathways contribute indirect, bundle-specific effects to cortico-cortical coupling. Using resting-state fMRI data from the Human Connectome Project, we quantified pathway-level mediation effects across GM-WM-GM units and found that WM BOLD signals significantly mediated GM-GM associations, with clear tract-dependent heterogeneity. Building upon this, we examined how dynamic features of WM BOLD signals relate to time-varying intra-cortical FC. We found that temporal variability of WM signals, rather than their mean amplitudes, more closely tracked fluctuations in GM-GM dynamic connectivity, with correlations reaching approximately 0.4 across specific tracts. Together, these results indicate that WM BOLD signals are related to how cortical regions interact, underscoring their integral role in large-scale brain network organization.

neuroscience↗

BrainVAE: Exploring the role of white matter BOLD in preclinical Alzheimer disease classification

INTRODUCTIONLike gray matter (GM), white matter (WM) BOLD functional signals change in preclinical AD. However, the potential of WM BOLD for identifying preclinical AD remains underexplored. METHODSWe developed BrainVAE, a transformer-based variational autoencoder with interpretability, to classify preclinical AD and normal controls using resting-state fMRI data. We benchmarked BrainVAE against nine alternative models under three input configurations: WM-only, GM-only, and combined WM+GM. Interpretability analysis was also performed to investigate each brain regions contribution to the classification task. RESULTSBrainVAE outperformed other models and performed well (accuracy = 83.42%, F1-score = 91.62%, AUC = 64.50%) using the combined input compared to WM-only and GM-only. Specific WM bundles--including corpus callosum, fornix, and corticospinal tract--were among the most influential features contributing to the classification. DISCUSSIONIncorporating WM BOLD signals improves the distinction of preclinical AD from controls, underscoring the potential role of WM BOLD features for detecting early-stage AD. HighlightsO_LIBrainVAE integrates white and gray matter BOLD signals for classification of pre-AD and controls. C_LIO_LIBrainVAE achieves high accuracy (83.42%) and F1-score (91.62%) in identifying pre-AD. C_LIO_LIModels using combined WM+GM inputs outperform those using WM-only or GM-only inputs. C_LIO_LIWM regions, such as corpus callosum and fornix, contribute significantly to model predictions. C_LIO_LIResults suggest WM BOLD signals are informative markers for early AD detection. C_LI

neuroscience↗

White matter geometry confounds Diffusion Tensor Imaging Along Perivascular Space (DTI-ALPS) measures

IntroductionThe perivascular space (PVS) is integral to glymphatic function, facilitating fluid exchange and waste clearance in the brain. Diffusion Tensor Imaging Along the Perivascular Space (DTI-ALPS) has been proposed as a non-invasive marker of perivascular diffusion, yet its specificity remains unclear. ALPS measures assume that radial asymmetry in white matter diffusivity predominantly reflects PVS contributions. However, anatomical and microstructural confounds may influence these metrics. MethodsWe systematically evaluated potential biases in ALPS-derived measures using high-resolution, multi-shell diffusion MRI from the Human Connectome Project (HCP) and high-field imaging. Specifically, we examined (1) the prevalence of radial asymmetry across white matter, (2) the influence of crossing fibers on ALPS indices, (3) the impact of axonal undulations and dispersion, and (4) the spatial alignment of vasculature with white matter in ALPS-associated regions. ResultsRadial asymmetry is widespread across white matter and persists even at high b-values, suggesting a dominant contribution from axonal geometry rather than faster PVS-specific diffusion. Crossing fibers significantly inflate ALPS indices, with greater radial asymmetry observed in regions with a greater prevalence of crossing fibers. Furthermore, anisotropic axonal dispersion and undulations introduce systematic asymmetry independent of perivascular diffusion. Finally, high-resolution vascular imaging reveals substantial heterogeneity in medullary vein orientation, challenging the assumption that PVS consistently aligns with the left-right axis in ALPS regions. ConclusionALPS indices are significantly influenced by white matter microstructure, including fiber crossings, undulations, and dispersion. These findings suggest that ALPS-derived metrics may not provide a direct measure of glymphatic function but rather reflect underlying axonal geometry. Interpretations of ALPS-derived metrics as biomarkers of glymphatic function must consider these anatomical complexities, and future studies should integrate advanced modeling approaches to disentangle perivascular contributions from white matter structure.

neuroscience↗

The relationship of white matter tract orientation to vascular geometry in the human brain

The white matter of the human brain exhibits highly ordered anisotropic structures of both axonal nerve fibers and cerebral vasculature. Separately, the anisotropic nature of white matter axons and white matter vasculature have been shown to cause an orientation dependence on various MRI contrasts used to study the structure and function of the brain; however, little is known of the relationship between axonal and vascular orientations. Thus, the aim of this study is to compare the orientation between nerve fibers and vasculature within the white matter. To do this, we use diffusion MRI and susceptibility weighted imaging acquired in the same healthy young adult volunteers and analyze the alignment between white matter fibers and blood vessels in different brain regions, and along different pathways, to determine the degree of alignment between these structures. We first describe vascular orientation throughout the brain and note several regions with consistent orientations across individuals. Next, we find that vasculature does not necessarily align with the dominant direction of white matter in many regions, but, due to the presence of crossing fiber populations, does align with at least some white matter within each MRI voxel. Even though the spatial patterns of blood vessels run in parallel to several white matter tracts, they do not do so along the entire pathway, nor for all pathways, suggesting that vasculature does not supply/drain blood in a tract-specific manner. Overall, these findings suggest that the vascular architecture within the white matter is closely related to, but not the same as, the organization of neural pathways. This study contributes to a better understanding of the microstructural arrangement of the brain and may have implications for interpreting neuroimaging data in health and disease.

neuroscience↗

Brain structure and activity predicting cognitive maturation in adolescence

Cognitive abilities of primates, including humans, continue to improve through adolescence 1,2. While a range of changes in brain structure and connectivity have been documented 3,4, how they affect neuronal activity that ultimately determines performance of cognitive functions remains unknown. Here, we conducted a multilevel longitudinal study of monkey adolescent neurocognitive development. The developmental trajectory of neural activity in the prefrontal cortex accounted remarkably well for working memory improvements. While complex aspects of activity changed progressively during adolescence, such as the rotation of stimulus representation in multidimensional neuronal space, which has been implicated in cognitive flexibility, even simpler attributes, such as the baseline firing rate in the period preceding a stimulus appearance had predictive power over behavior. Unexpectedly, decreases in brain volume and thickness, which are widely thought to underlie cognitive changes in humans 5 did not predict well the trajectory of neural activity or cognitive performance changes. Whole brain cortical volume in particular, exhibited an increase and reached a local maximum in late adolescence, at a time of rapid behavioral improvement. Maturation of long-distance white matter tracts linking the frontal lobe with areas of the association cortex and subcortical regions best predicted changes in neuronal activity and behavior. Our results provide evidence that optimization of neural activity depending on widely distributed circuitry effects cognitive development in adolescence.

neuroscience↗

CHANGES IN MUSCLE QUALITY FOLLOWING SHORT-TERM RESISTANCE TRAINING IN OLDER ADULTS: A COMPARISON OF ECHO INTENSITY AND TEXTURE ANALYSIS

BackgroundSkeletal muscle echo intensity (EI) is associated with functional outcomes in older adults, but resistance training interventions have shown mixed results. Texture analysis has been proposed as a novel approach for assessing muscle quality, as it captures spatial relationships between pixels. PurposeTo examine changes in first-order (EI) and second-order (texture) features of muscle quality following lower-body resistance training in older adults. MethodsTwelve older adults (2 males, 10 females; mean {+/-} SD age = 70 {+/-} 5 years) completed 6 weeks of progressive resistance training, consisting of twice-weekly sessions at 85% of estimated 1RM. Pre- and post-intervention assessments included ultrasound imaging of the rectus femoris (RF) and vastus lateralis (VL), 5-repetition maximum (5RM) leg extension strength, and maximal voluntary isometric contraction (MVIC) force. Ultrasound images were analyzed for EI and texture features using gray-level co-occurrence matrix (GLCM) analysis. ResultsLarge improvements were observed in 5RM leg extension strength (p < 0.001, d = 2.09), MVIC force (p = 0.006, d = 0.969), and RF EI (uncorrected: p = 0.003, d = 0.727; corrected: p = 0.012, d = 0.864). No significant changes were observed in muscle size, VL EI, or texture features for either muscle. ConclusionsShort-term resistance training improved strength and RF muscle quality as measured by EI. However, texture analysis features were not sensitive to changes following training. These findings suggest that traditional EI measures may be more appropriate than texture analysis for tracking changes in muscle quality following resistance training in older adults. NEW & NOTEWORTHYWe studied muscle quality changes after 6 weeks of resistance training in older adults, comparing traditional EI to texture analysis. Despite significant strength gains, only RF EI improved, with minimal changes in muscle size, VL EI, or texture parameters. Surprisingly, texture analysis was less sensitive than traditional EI in detecting muscle quality changes. Our results suggest that conventional EI measures may be more suitable for evaluating short-term adaptations to resistance training in older adults.

physiology↗

Spatiospectral image processing workflow considerations for advanced MR spectroscopy of the brain

Magnetic resonance spectroscopy (MRS) is one of the few non-invasive imaging modalities capable of making neurochemical and metabolic measurements in vivo. Traditionally, the clinical utility of MRS has been narrow. The most common use has been the "single-voxel spectroscopy" variant to discern the presence of a lactate peak in the spectra in one location in the brain, typically to evaluate for ischemia in neonates. Thus, the reduction of rich spectral data to a binary variable has not classically necessitated much signal processing. However, scanners have become more powerful and MRS sequences more advanced, increasing data complexity and adding 2 to 3 spatial dimensions in addition to the spectral one. The result is a spatially- and spectrally-variant MRS image ripe for image processing innovation. Despite this potential, the logistics for robustly accessing and manipulating MRS data across different scanners, data formats, and software standards remain unclear. Thus, as research into MRS advances, there is a clear need to better characterize its image processing considerations to facilitate innovation from scientists and engineers. Building on established neuroimaging standards, we describe a framework for manipulating these images that generalizes to the voxel, spectral, and metabolite level across space and multiple imaging sites while integrating with LCModel, a widely used quantitative MRS peak-fitting platform. In doing so, we provide examples to demonstrate the advantages of such a workflow in relation to recent publications and with new data. Overall, we hope our characterizations will lower the barrier of entry to MRS processing for neuroimaging researchers.

bioengineering↗

Whole-brain, gray and white matter time-locked functional signal changes with simple tasks and model-free analysis

Recent studies have revealed the production of time-locked blood oxygenation-level dependent (BOLD) functional MRI (fMRI) signals throughout the entire brain in response to a task, challenging the idea of sparse and localized brain functions, and highlighting the pervasiveness of potential false negative fMRI findings. In these studies, whole-brain refers to gray matter regions only, which is the only tissue traditionally studied with fMRI. However, recent reports have also demonstrated reliable detection and analyses of BOLD signals in white matter which have been largely ignored in previous reports. Here, using model-free analysis and simple tasks, we investigate BOLD signal changes in both white and gray matters. We aimed to evaluate whether white matter also displays time-locked BOLD signals across all structural pathways in response to a stimulus. We find that both white and gray matter show time-locked activations across the whole-brain, with a majority of both tissue types showing statistically significant signal changes for all task stimuli investigated. We observed a wide range of signal responses to tasks, with different regions showing very different BOLD signal changes to the same task. Moreover, we find that each region may display different BOLD responses to different stimuli. Overall, we present compelling evidence that the whole brain, including both white and gray matter, show time-locked activation to multiple stimuli, not only challenging the idea of sparse functional localization, but also the prevailing wisdom of treating white matter BOLD signals as artefacts to be removed.

neuroscience↗

Superficial white matter across the lifespan: volume, thickness, change, and relationship with cortical features

Superficial white matter (SWM) represents a significantly understudied part of the human brain, despite comprising a large portion of brain volume and making up a majority of cortical structural connections. Using multiple, high-quality, datasets with large sample sizes (N=2421, age range 5-100) in combination with methodological advances in tractography, we quantified features of SWM volume and thickness across the brain and across the lifespan. We address four questions: (1) How does U-fiber volume change with age? (2) What does U-fiber thickness look like across the brain? (3) How does SWM thickness change with age? (4) Are there relationships between SWM thickness and cortical features? Our main findings are that (1) SWM volume shows unique volumetric trajectories with age that are distinct from gray matter and other white matter trajectories; (2) SWM thickness varies across the brain, with patterns robust across individuals and across the population at the region-level and vertex-level; (3) SWM shows nonlinear changes across the lifespan that vary across regions; and (4) SWM thickness is associated with cortical thickness and curvature. For the first time, we show that SWM volume follows a similar trend as overall white matter volume, peaking at a similar time in adolescence, leveling off throughout adulthood, and decreasing with age thereafter. Notably, the relative fraction of total brain volume of SWM continuously increases with age, and consequently takes up a larger proportion of total white matter volume, unlike the other tissue types that decrease with respect to total brain volume. This study represents the first characterization of SWM features across the lifespan and provides the background for characterizing normal aging and insight into the mechanisms associated with SWM development and decline.

neuroscience↗

Along-tract quantification of resting-state BOLD hemodynamic response functions in white matter

Detailed knowledge of the BOLD hemodynamic response function (HRF) is crucial for accurate analysis and interpretation of functional MRI data. Considerable efforts have been made to characterize the HRF in gray matter (GM) but much less is known about BOLD effects in white matter (WM). However, recent reports have demonstrated reliable detection and analyses of WM BOLD signals after stimulation and in a resting state. WM and GM differ in energy requirements and blood flow, so neurovascular couplings may well be different. We aimed to derive a comprehensive characterization of the HRF in WM across a population, including accurate measurements of its shape and its variation along and between WM pathways, using resting-state fMRI acquisitions. Our results show that the HRF is significantly different between WM and GM. Features of the HRF, such as a prominent initial dip, show strong relationships with features of the tissue microstructure derived from diffusion imaging, and these relationships differ between WM and GM, consistent with BOLD signal fluctuations reflecting different energy demands and differences in neurovascular coupling between tissues of different composition. We also show that the HRF varies significantly along WM pathways, and is different between different WM pathways. Thus, much like in GM, changes in flow and/or oxygenation are different for different parts of the WM. These features of the HRF in WM are especially relevant for interpretation of the biophysical basis of BOLD effects in WM.

neuroscience↗

Short superficial white matter and aging: a longitudinal multi-site study of 1,293 subjects and 2,711 sessions

It is estimated that short association fibers, or "U-shaped" fibers running immediately beneath the cortex, may make up as much as 60% of the total white matter volume. However, these have been understudied relative to the long-range association, projection, and commissural fibers of the brain. This is largely because of limitations of diffusion MRI fiber tractography, which is the primary methodology used to non-invasively study the white matter connections. Inspired by recent anatomical considerations and methodological improvements in U-fiber tractography, we aim to characterize changes in these fiber systems in cognitively normal aging, which provide insight into the biological foundation of age-related cognitive changes, and a better understanding of how age-related pathology differs from healthy aging. To do this, we used three large, longitudinal and cross-sectional datasets (N = 1293 subjects, 2711 sessions) to quantify microstructural features and length/volume features of several U-fiber systems. We find that axial, radial, and mean diffusivities show positive associations with age, while fractional anisotropy has negative associations with age in superficial white matter throughout the entire brain. These associations were most pronounced in the frontal, temporal, and temporoparietal regions. Moreover, measures of U-fiber volume and length decrease with age in a heterogenous manner across the brain, with prominent effects observed for pre- and post-central gyri. These features, and their variations with age, provide the background for characterizing normal aging, and, in combination with larger association pathways and gray matter microstructural features, may provide insight into fundamental mechanisms associated with aging and cognition.

neuroscience↗

Aging and white matter microstructure and macrostructure: a longitudinal multi-site diffusion MRI study of 1,184 participants

Quantifying the microstructural and macrostructural geometrical features of the human brains connections is necessary for understanding normal aging and disease. Here, we examine brain white matter diffusion magnetic resonance imaging data from one cross-sectional and two longitudinal datasets totaling in 1184 subjects and 2236 sessions of people aged 50-97 years. Data was drawn from well-established cohorts, including the Baltimore Longitudinal Study of Aging dataset, Cambridge Centre for Ageing Neuroscience dataset, and the Vanderbilt Memory & Aging Project. Quantifying 4 microstructural features and, for the first time, 11 macrostructure-based features of volume, area, and length across 120 white matter pathways, we apply linear mixed effect modeling to investigate changes in pathway-specific features over time, and document large age associations within white matter. Conventional diffusion tensor microstructure indices are the most age-sensitive measures, with positive age associations for diffusivities and negative age associations with anisotropies, with similar patterns observed across all pathways. Similarly, pathway shape measures also change with age, with negative age associations for most length, surface area, and volume-based features. A particularly novel finding of this study is that while trends were homogeneous throughout the brain for microstructure features, macrostructural features demonstrated heterogeneity across pathways, whereby several projection, thalamic, and commissural tracts exhibited more decline with age compared to association and limbic tracts. The findings from this large-scale study provide a comprehensive overview of the age-related decline in white matter and demonstrate that macrostructural features may be more sensitive to heterogeneous white matter decline. Therefore, leveraging macrostructural features may be useful for studying aging and could have widespread implications for a variety of neurodegenerative disorders.

neuroscience↗

Dynamic variations of resting-state BOLD signal spectra in white matter

Recent studies have demonstrated that the mathematical model used for analyzing and interpreting fMRI data in gray matter (GM) is inappropriate for detecting or describing blood-oxygenation-level-dependent (BOLD) signals in white matter (WM). In particular the hemodynamic response function (HRF) which serves as the regressor in general linear models is different in WM compared to GM. We recently reported measurements of the frequency contents of resting-state time courses in WM that showed distinct power spectra which depended on local structural-vascular-functional associations. In addition, multiple studies of GM have revealed how functional connectivity between regions, as measured by the correlation between BOLD time series, varies dynamically over time. We therefore investigated whether and how BOLD signals from WM in a resting state varied over time. We measured voxel-wise spectrograms, which reflect the time-varying spectral patterns of WM time courses. The results suggest that the spectral patterns are non-stationary but could be categorized into five modes that recurred over time. These modes showed distinct spatial distributions of their occurrences and durations, and the distributions were highly consistent across individuals. In addition, one of the modes exhibited a strong coupling of its occurrence between GM and WM across individuals, and two communities of WM voxels were identified according to the hierarchical structures of transitions among modes. Moreover, the total number of transitions in each community predicts specific human behaviors. Last, these modes are coupled to the shape of instantaneous HRFs. Our findings extend previous studies and reveal the non-stationary nature of spectral patterns of BOLD signals over time, providing a spatial-temporal-frequency characterization of resting-state signals in WM.

neuroscience↗

Prevalence of white matter pathways coming into a single diffusion MRI voxel orientation: the bottleneck issue in tractography

Characterizing and understanding the limitations of diffusion MRI fiber tractography is a prerequisite for methodological advances and innovations which will allow these techniques to accurately map the connections of the human brain. The so-called "crossing fiber problem" has received tremendous attention and has continuously triggered the community to develop novel approaches for disentangling distinctly oriented fiber populations. Perhaps an even greater challenge occurs when multiple white matter bundles converge within a single voxel, or throughout a single brain region, and share the same parallel orientation, before diverging and continuing towards their final cortical or sub-cortical terminations. These so-called "bottleneck" regions contribute to the ill-posed nature of the tractography process, and lead to both false positive and false negative estimated connections. Yet, as opposed to the extent of crossing fibers, a thorough characterization of bottleneck regions has not been performed. The aim of this study is to quantify the prevalence of bottleneck regions. To do this, we use diffusion tractography to segment known white matter bundles of the brain, and assign each bundle to voxels they pass through and to specific orientations within those voxels (i.e. fixels). We demonstrate that bottlenecks occur in greater than 50-70% of fixels in the white matter of the human brain. We find that all projection, association, and commissural fibers contribute to, and are affected by, this phenomenon, and show that even regions traditionally considered "single fiber voxels" often contain multiple fiber populations. Together, this study shows that a majority of white matter presents bottlenecks for tractography which may lead to incorrect or erroneous estimates of brain connectivity or quantitative tractography (i.e., tractometry), and underscores the need for a paradigm shift in the process of tractography and bundle segmentation for studying the fiber pathways of the human brain.

neuroscience↗

Fiber tractography bundle segmentation depends on scanner effects, acquisition, diffusion sensitization, and bundle segmentation workflow

When investigating connectivity and microstructure of white matter pathways of the brain using diffusion tractography bundle segmentation, it is important to understand potential confounds and sources of variation in the process. While cross-scanner and cross-protocol effects on diffusion microstructure measures are well described (in particular fractional anisotropy and mean diffusivity), it is unknown how potential sources of variation effect bundle segmentation results, which features of the bundle are most affected, where variability occurs, nor how these sources of variation depend upon the method used to reconstruct and segment bundles. In this study, we investigate six potential sources of variation, or confounds, for bundle segmentation: variation (1) across scan repeats, (2) across scanners, (3) across vendors (4) across acquisition resolution, (5) across diffusion schemes, and (6) across diffusion sensitization. We employ four different bundle segmentation workflows on two benchmark multi-subject cross-scanner and cross-protocol databases, and investigate reproducibility and biases in volume overlap, shape geometry features of fiber pathways, and microstructure features within the pathways. We find that the effects of acquisition protocol, in particular acquisition resolution, result in the lowest reproducibility of tractography and largest variation of features, followed by vendor-effects, scanner-effects, and finally diffusion scheme and b-value effects which had similar reproducibility as scan-rescan variation. However, confounds varied both across pathways and across segmentation workflows, with some bundle segmentation workflows more (or less) robust to sources of variation. Despite variability, bundle dissection is consistently able to recover the same location of pathways in the deep white matter, with variation at the gray matter/ white matter interface. Next, we show that differences due to the choice of bundle segmentation workflows are larger than any other studied confound, with low-to-moderate overlap of the same intended pathway when segmented using different methods. Finally, quantifying microstructure features within a pathway, we show that tractography adds variability over-and-above that which exists due to noise, scanner effects, and acquisition effects. Overall, these confounds need to be considered when harmonizing diffusion datasets, interpreting or combining data across sites, and when attempting to understand the successes and limitations of different methodologies in the design and development of new tractography or bundle segmentation methods.

neuroscience↗

Pandora: 4-D white matter bundle population-based atlasesderived from diffusion MRI fiber tractography

Brain atlases have proven to be valuable neuroscience tools for localizing regions of interest and performing statistical inferences on populations. Although many human brain atlases exist, most do not contain information about white matter structures, often neglecting them completely or labelling all white matter as a single homogenous substrate. While few white matter atlases do exist based on diffusion MRI fiber tractography, they are often limited to descriptions of white matter as spatially separate "regions" rather than as white matter "bundles" or fascicles, which are well-known to overlap throughout the brain. Additional limitations include small sample sizes, few white matter pathways, and the use of outdated diffusion models and techniques. Here, we present a new population-based collection of white matter atlases represented in both volumetric and surface coordinates in a standard space. These atlases are based on 2443 subjects, and include 216 white matter bundles derived from 6 different state-of-the-art tractography techniques. This atlas is freely available and will be a useful resource for parcellation and segmentation.

neuroscience↗

Practical gradient non-linearity correction of multi-site diffusion weighted MRI with empirical field maps

BackgroundAchieving inter-site / inter-scanner reproducibility of diffusion weighted magnetic resonance imaging (DW-MRI) metrics has been challenging given differences in acquisition protocols, analysis models, and hardware factors. PurposeMagnetic field gradients impart scanner-dependent spatial variations in the applied diffusion weighting that can be corrected if the gradient nonlinearities are known. However, retrieving manufacturer nonlinearity specifications is not well supported and may introduce errors in interpretation of units or coordinate systems. We propose an empirical approach to mapping the gradient nonlinearities with sequences that are supported across the major scanner vendors. Study TypeProspective observational study SubjectsA spherical isotropic diffusion phantom, and a single human control volunteer Field Strength/Sequence3T (two scanners). Stejskal-Tanner spin echo sequence with b-values of 1000, 2000 s/mm2 with 12, 32, and 384 diffusion gradient directions per shell. AssessmentWe compare the proposed correction with the prior approach using manufacturer specifications against typical diffusion pre-processing pipelines (i.e., ignoring spatial gradient nonlinearities). In phantom data, we evaluate metrics against the ground truth. In human and phantom data, we evaluate reproducibility across scans, sessions, and hardware. Statistical TestsWilcoxon rank-sum test between uncorrected and corrected data. ResultsIn phantom data, our correction method reduces variation in mean diffusivity across sessions over uncorrected data (p<0.05). In human data, we show that this method can also reduce variation in mean diffusivity across scanners (p<0.05). ConclusionOur method is relatively simple, fast, and can be applied retroactively. We advocate incorporating voxel-specific b-value and b-vector maps should be incorporated in DW-MRI harmonization preprocessing pipelines to improve quantitative accuracy of measured diffusion parameters.

neuroscience↗

Registration-free Distortion Correction of Diffusion Weighted MRI

Diffusion magnetic resonance images may suffer from geometric distortions due to susceptibility induced off resonance fields, which cause geometric mismatch with anatomical images and ultimately affect subsequent quantification of microstructural or connectivity indices. State-of-the art diffusion distortion correction methods typically require data acquired with reverse phase encoding directions, resulting in varying magnitudes and orientations of distortion, which allow estimation of an undistorted volume. Alternatively, additional field maps acquisitions can be used along with sequence information to determine warping fields. However, not all imaging protocols include these additional scans and cannot take advantage of state-of-the art distortion correction. To avoid additional acquisitions, structural MRI (undistorted scans) can be used as registration targets for intensity driven correction. In this study, we aim to (1) enable susceptibility distortion correction with historical and/or limited diffusion datasets that do not include specific sequences for distortion correction and (2) avoid the computationally intensive registration procedure typically required for distortion correction using structural scans. To achieve these aims, we use deep learning (3D U-nets) to synthesize an undistorted b0 image that matches geometry of structural T1w images and intensity contrasts from diffusion images. Importantly, the training dataset is heterogenous, consisting of varying acquisitions of both structural and diffusion. We apply our approach to a withheld test set and show that distortions are successfully corrected after processing. We quantitatively evaluate the proposed distortion correction and intensity-based registration against state-of-the-art distortion correction (FSL topup). The results illustrate that the proposed pipeline results in b0 images that are geometrically similar to non-distorted structural images, and more closely match state-of-the-art correction with additional acquisitions. In addition, we show generalizability of the proposed approach to datasets that were not in the original training / validation / testing datasets. These datasets included varying populations, contrasts, resolutions, and magnitudes and orientations of distortion and show efficacious distortion correction. The method is available as a Singularity container, source code, and an executable trained model to facilitate evaluation.

bioengineering↗