Search bioRxiv⌕ Search

Biology subjects

Adame-Gonzalez, W.

Publications and source records attributed to Adame-Gonzalez, W..

4 recordsLinked to original sources

T2 relaxometry for myelin water fraction: an ex vivo brain imaging study

Abstract Introduction: Myelin water imaging provides a non-invasive approach for indirectly investigating myelin content of the brain by magnetic resonance Imaging (MRI). Myelin water fraction (MWF) reflects the fraction of water signal associated with water trapped between myelin layers. Postmortem imaging provides a unique opportunity to validate MWF metrics against gold-standard postmortem neuropathology. However, there is a need for validated sequences that would be applicable in postmortem settings. In this study, we validated and compared the applicability of turbo spin echo (TSE) and gradient-and-spin-echo (GRASE) techniques for myelin water imaging in formaldehyde fixed postmortem human brains. Methods: 40 postmortem human brain hemispheres were scanned with TSE and GRASE sequences. Acquired data were reconstructed using a non-parametric multicomponent T2 relaxometry approach using a consistent framework to support comparison between GRASE- and TSE-derived measures. Agreement between derived measures was quantified at both voxel and regional level. Maps derived from the full 32-echo GRASE reconstruction were compared against a truncated 14-echo reconstruction to examine the contribution of the longer echoes to the derived maps. Finally, a random forest regression model was trained based on TSE data to predict the GRASE-derived MWF maps. Results: Both sequences provided robust multicomponent T2 characterization across the brain, and the derived measures showed anatomical patterns consistent with expected differences across tissue types. TSE and GRASE derived maps had moderate to strong agreement at voxel (0.41< {rho} < 0.82, all pFDR<0.001) and regional levels (0.87< {rho} < 0.98, all pFDR<0.001), with consistently stronger agreement observed for regional metrics. Echo reduction comparisons between the full 32-echo GRASE reconstruction and a truncated 14-echo reconstruction showed minimal impact of echo truncation (all {rho} > 0.98, pFDR < 0.001). The nonlinear random forest regression model trained on TSE maps was able to accurately reproduce the MWF maps derived from GRASE (r = 0.91, RMSE = 8.87). Discussion: TSE and GRASE32 capture strongly related multicomponent T2 information in fixed postmortem human brain tissue, but with systematic and tissue-dependent quantitative differences across derived measures. These differences suggest that direct interchangeability should not be assumed and that cross-sequence mapping or calibration is required when quantitative equivalence is desired.

neuroscience↗

Neuronal quantification in the primary motor cortex of mouse brains fixed with solutions from human gross anatomy laboratories

Background: Brain banks usually provide small tissue blocks fixed by immersion in neutral-buffered formalin (NBF). While still underexploited for research, gross anatomy laboratories could provide full brains fixed by perfusion with solutions better suited for gross anatomy dissection. However, the chemicals in these solutions might have a different impact on histology protocols for cell quantification than in NBF-fixed brains. The main goal of this study is to compare the effects on the number and size of labeled neurons of the primary motor cortex (PMC) of mouse brains fixed with three different solutions: (1) NBF, typical of brain banks, (2) a saturated salt solution (SSS), and (3) an alcohol-formaldehyde solution (AFS), both used in human anatomy laboratories. Methods: 27 C57BL/6J mouse brains were perfused with the NBF (N=9), SSS (N=9) or AFS (N=9), then cut in 40-m slices and processed with immunohistochemistry to target neurons. Various quantitative variables were assessed manually and automatically on photomicrographs of 3 regions of interest (ROIs) of the PMC per specimen, namely the total and individual neuronal profile areas, number and diameters. The effects of the three fixatives on these variables were compared using ANOVA or Kruskal-Wallis, depending on the distribution. For measures on individual cells, a generalized linear mixed model was applied. Dice coefficients and correlations were applied to evaluate the agreement of the manual and automatic methods. Results: There was no significant difference between the brains fixed by the three fixatives for the total and individual cell areas, the total cell count and the cell diameters. The values obtained from manual and automatic measures had an overall good agreement (Dice coefficients > 0.79). Conclusion: It was found that the SSS and AFS had similar impacts on the quantitative variables in the tissue as the NBF. These results are promising for neuroscientists interested in using brains from anatomy laboratories for quantitative research on neurons from the PMC.

neuroscience↗

Ex vivo human brain volumetry: validation of magnetic resonance imaging measurements

BackgroundNeurodegenerative diseases are associated with brain atrophy. The volume of in vivo human brains is determined with various magnetic resonance imaging (MRI) measurement tools of which the validity has not been assessed against a gold standard. Here, we propose to validate the MRI brain volumes by scanning ex vivo-in situ specimens (i.e., anatomical heads), which allows the extraction of the brain after the scan to compare its volume with the gold standard water displacement method (WDM). MethodsWe acquired 3T MRI T2-weighted, T1-weighted, and MP2RAGE images of seven anatomical heads fixed with an alcohol-formaldehyde solution routinely used in anatomy laboratories and segmented the gray and white matter of the brain using two methods: 1) a manual intensity-based threshold segmentation using Display (MINC-ToolKit, McConnell BIC), and 2) an automatic Deep-Learning-based segmentation tool (SynthSeg). The brains were then extracted, and their volumes were measured with the WDM after the removal of their meninges and a midsagittal cut (to allow water penetration into the ventricles). Volumes from all methods were compared to the ground truth (WDM volumes) using a repeated-measures ANOVA. ResultsMean brain volumes, in cubic centimeters, were 1111.14{+/-}121.78 for WDM, 1020.29{+/-}70.01 for manual T2-weighted, 1056.29{+/-}90.54 for automatic T2-weighted, 1094.69{+/-}100.51 for automatic T1-weighted, 1066.56{+/-}96.52 for automatic MP2RAGE INV1, and 1156.18{+/-}121.87 for MP2RAGE INV2. All volumetry methods were significantly different (F=17.874; p<0.001) from the WDM volumes, except the automatic T1-weighted volumes. ConclusionWe demonstrate that SynthSeg accurately determines the brain volume in ex vivo-in situ T1-weighted MRI scans. Our results also suggest that given the contrast similarity between our ex vivo and in vivo sequences, the brain volumes of clinical studies are most probably sufficiently accurate, with some degree of underestimation depending on the sequence used.

neuroscience↗

FONDUE: Robust resolution-invariant denoising of MR Images using Nested UNets

Recent human neuroimaging studies tend to have increased magnetic resonance image (MRI) acquisition resolutions, seeking finer levels of detail and more accurate brain morphometry. However, higher-resolution images inherently contain greater amounts of noise contamination, leading to poorer quality brain morphometry if not addressed adequately. This study proposes a novel, robust, resolution-invariant deep learning method to denoise structural human brain MRIs. We explore denoising of T1-weighted (T1w) brain images from varying field strengths (1.5T to 7T), voxel sizes (1.2mm to 250{micro}m), scanner vendors (Siemens, GE, and Phillips), and diseased and healthy participants from a wide age range (young adults to aging individuals). Our proposed Fast-Optimized Network for Denoising through residual Unified Ensembles (FONDUE) method demonstrated stable denoising capabilities across multiple resolutions with performance comparable to the state-of-the-art methods. FONDUE was capable of denoising 0.5mm3 isotropic T1w images in under 3 minutes on an NVIDIA RTX 3090 GPU using less than 8GB of video memory. We have also made the repository of FONDUE as well as its trained weights publicly available on: https://github.com/waadgo/FONDUE.

neuroscience↗